My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
853
>
2300 - Underground Storage Tank Program
>
PR0231460
>
BILLING 1985-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 2:50:24 PM
Creation date
11/7/2018 12:29:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-1998
RECORD_ID
PR0231460
PE
2381
FACILITY_ID
FA0001369
FACILITY_NAME
7-ELEVEN INC. STORE #21756
STREET_NUMBER
853
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
02
SITE_LOCATION
853 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\853\PR0231460\BILLING 1985-1998.PDF
QuestysFileName
BILLING 1985-1998
QuestysRecordDate
8/10/2017 5:25:54 PM
QuestysRecordID
3568206
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iy�,uace*s <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD r <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <� ib' <br /> COMPLETE A SEPARATE FOAM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT O 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CL <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 8 TEMPORARY TANKCLOSURE ❑ 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: Yo N em; <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK 1.D.# �/ B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) D. TANK CAPACITY IN GALLONS: �4J <br /> II.TANKC TENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> a REGULAR 3 DIESEL <br /> A. t MOTOR VEHICLE FUEL ❑ 4 OIL B, C. UNLEADED 6 AVIATION GAS <br /> ❑ <br /> ❑ 2 PETROLEUM 71 Bo EMPTY 1 PRODUCT ❑ ibIUM ❑ 5 ,ET FUEL q GASAHOL L] 7 METHANOL <br /> UNLEADED <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER 95 UNKNOWN <br /> SYSTEM �SiNGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> 1 <br /> B. TANK BARE STEEL 2 STAINLESS STEEL ❑ 3 FIBERGLASS 4 STEEL CLAD WI FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ B POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 109% METHANOL COMPATIBLE WIERP <br /> (PrimaryTank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING ��UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> LINING IS LINING MATERIAL COMPATIBLE WITH 106% METHANOL? YES— NO <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ©'UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EOUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND,BOTH IFAPPLICABLF <br /> A. SYSTEM TYPE A U 1 SUCTION A(p PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 8 CONCRETE A U 7 STEEL WI COATING A U 8 100% METHANOL COMPATIBLE WIFRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A(5>95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION Z11 AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING3 INTERSTITIAL <br /> ❑ MONITORING [—] 99 OTHER <br /> V.TANK LEAK DETECTION <br /> 0 1 VISUAL CHECK 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> �ANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/CAYIYR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH � <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? YES ❑ NO L_-_' <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRFCT <br /> APPLICANTS NAME DATE <br /> IPRINTED d SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> STATE l.D.# <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> S-IS-r <br /> FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> '� 1 f, FOR6034B-R5 <br /> i <br /> J <br />
The URL can be used to link to this page
Your browser does not support the video tag.