Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2650
>
2300 - Underground Storage Tank Program
>
PR0232573
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 11:33:41 AM
Creation date
11/7/2018 3:42:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0232573
PE
2361
FACILITY_ID
FA0003941
FACILITY_NAME
ORCHARD SUPPLY HARDWARE #1570
STREET_NUMBER
2650
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21307061
CURRENT_STATUS
02
SITE_LOCATION
2650 MACARTHUR DR STE A
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MACARTHUR\2650\PR0232573\COMPLIANCE INFO 1992-2014.PDF
QuestysFileName
COMPLIANCE INFO 1992-2014
QuestysRecordDate
8/2/2017 3:55:42 PM
QuestysRecordID
3544390
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
该页面上没有批注。
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY � DATE <br /> PR# <br /> *VIRONMENTAL HEALTH DEPARTMENT PAGE <br /> 304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility Name — 6\ Sttyly -MvA feFacility Address 60 h - nU (lb T�rz�.t . <br /> Facilty Contact a6V-eA Title So� SL,IDZVV15U(Phone # 9 3 �3 -3 ti Q <br /> UST# f Product US�� UST#_Product UST#_Product UST# Product <br /> Overfill Prevention: [9'AudibleNisual 0 Mechanical Monitoring Panel: 260 <br /> Piping System: Erbravity ❑ Pressure ❑ Suction // Violations: Ll-Minor ❑M�)or <br /> Automatic Pum Shut Down Satisfies CCR 2636 ❑Yes 2'40Dispenser Pan: ❑Yes o <br /> INSPECTION TYPE: outine ❑Monitoring Certification ❑Complaint ❑install ❑Removal ❑Repair/Upgrade <br /> COMPANY NAME: TECHNICIAN NAME: PHONE: <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 20 CCR 2712 (b) Maintenance &monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> ,�. <br /> month/36 month) 21 CCR 2636 (f)(4) Annual line tightness test <br /> 3� R 2711(b) & (c) Current State Forms A& B 22 CCR 2630 (d) Annual line leak detector test <br /> 4 HSC 25292.2 Certification of financial 23 CCR 2630 (d) Annual monitoring certification <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring of suction <br /> chief financial officer piping that is not continuously <br /> 5 CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2636 (a) Conventional suction piping <br /> 6 CCR 2636 (c)(1) All releases in secondary piping shall have continuous <br /> flow to a collection sump monitoring &21 containment <br /> 7 HSC 25291 (e) Water in secondary(20)cant 26 CCR 2643 (e) Biennial tightness test of gravity <br /> 8 HSC 25291 (f) Automatic line leak detector(s) piping that is not continuously <br /> 9 CCR 2636 (f)(1) Continuous monitoring system monitored <br /> for underground piping 27 CCR 2662 Upgrade requirements for UST <br /> 10 CCR 2632 (c)(2) Continuous monitoring system system <br /> for UST 28 CCR 2661 Permit to repair UST system <br /> 11 HSC 25291(a)(2) Secondary containment for 29 HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12 CCR 2636 (f)(1) Continuous monitoring system 30 NSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system system <br /> 13 CCR 2635 (b)(1) Spill container 31 HSC 25298 (b) Permit to temporarily close UST <br /> 14 CCR 2635 (b)(2) Overfill prevention system system <br /> 15 CCR 2631 (a) Primary containment is product- 32 HSC 25298 (c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 20 cont analyzed and <br /> 16 MSC 25292.1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640 (e) Single wall component within <br /> 17 CCR 2650 Recording/reporting 1 000'of Public Well, no ELD <br /> unauthorized release 35 CCR 2635(a)(2)(A)Cathodic protection testing <br /> 18 j CCR 2632 (d) Monitoring & response plan 36 H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19 CCR 2712 (i) Monitoring &response plan is 37 Violation(s) not listed above <br /> on site <br /> EHD INSPECTOR: ' PHONE: '�Qe-3gU <br /> RECEIVED BY: TITLE:�, C4e-h 6'c e v 5 or-- <br /> UNMIWSTMNSP(rev 7124/02) <br />
The URL can be used to link to this page
Your browser does not support the video tag.