My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1987
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1071
>
2300 - Underground Storage Tank Program
>
PR0231431
>
INSTALL_1987
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 11:01:30 AM
Creation date
11/7/2018 4:08:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1987
RECORD_ID
PR0231431
PE
2361
FACILITY_ID
FA0000514
FACILITY_NAME
MAIN STREET SHELL*
STREET_NUMBER
1071
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21707011
CURRENT_STATUS
02
SITE_LOCATION
1071 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\1071\PR0231431\INSTALL 1987.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />0 0 <br />1 <br />Function Key - F: Depress prior to function com- <br />mand codes. <br />Print Key - PRINT: Used to select copy for (1) In- <br />' <br />ventory Status, (2) Shift Report, (3) Product <br />Delivery (drop), (4) Alarm Status and (5) Last <br />Leak Test Report. Enter the number of the report <br />' <br />requested and press ENT. <br />Silence Key - SILENCE: Used to reset remote <br />' <br />alarm relays. <br />Mode Program/Run Key: Provided with a <br />removable key to eliminate accidental program <br />information entry. The key is positioned in the <br />' <br />Program mode for system start-up and to enter <br />function values. When the key is positioned in <br />the Run mode, all functions can be interrogated <br />but no data entry values can be changed. It is <br />' <br />recommended that the key is positioned in the <br />Run mode, then removed and kept in the <br />manager's office until a program change is re- <br />quired. <br />' 6.0 PROGRAMMING INFORMATION <br />' Enter the set-up information into the controller by <br />using the function codes listed in Table 6-1: Function <br />Codes. Refer to Section 5.0 for keyboard function in- <br />formation. <br />IMPORTANT: The Mode key must be switched to the <br />program position in order to enter set-up information. <br />All system input should be preceded by activating <br />' Function 290. This will disable the printer and allow <br />changes to set-up data without activating warning <br />reports or product increases to the system's set-up <br />' data. When changes have been completed, activate <br />Function 291 to restore the system to field operation. <br />When set-up information is complete, the Mode key <br />' should be positioned into the Run mode and the key <br />removed. With the Mode key positioned in the Run <br />mode, functions can be interrogated but no set-up <br />input can be changed. <br />' Information is entered by pressing the Function key, <br />F, then pressing the correct Function Code (i.e.290). <br />(see Table 6-1 for function code listings), and press- <br />ing the Enter key, ENT. Then press data entry keys <br />and your entered data will be displayed on the LCD. <br />Now press the Enter key, ENT, to store the changes <br />in the controller's memory. <br />6.1 Programming Time, Date, Station Name <br />and Address <br />Turn the Mode key to program and press F, 290 <br />and the Enter key, ENT. <br />6.1.1 Time: Press F, 90 and ENT. Enter the cor- <br />rect time, (i.e. 9.23.0=AM, 1=PM) and press ENT. <br />6.1.2 Date: Press F, 91 and ENT. Enter the cor- <br />rect date (i.e. 1-01-90) and press ENT. Enter the <br />correct day of the week (i.e. 1=Sun., 2=Mon., <br />3=Tues., etc.), press ENT. <br />6.1.3 Name: Press F, 94 and ENT. Enter the <br />station's name by using the Date Entry key, (I), <br />to advance the alphabet and Data Entry key, <br />C/CE, to reverse the alphabet. To move right for <br />an entry, press the Command key LO. To move <br />to the left, press Command key HI. When the cor- <br />rect name has been entered, press ENT. <br />6.1.4 Address: Press F, 95 and ENT. Enter the <br />correct street address by using the keys <br />described in Sections 5.0 and 6.0. <br />6.1.5 City, State and ZIP: Press F, 96 and ENT. <br />Enter correct city, state and ZIP, now press ENT. <br />Press F, 291 and ENT, to clear Calibration <br />mode. Press PRINT, 1 and ENT, and check print- <br />out to verify the correct time, date, name and ad- <br />dress. <br />No. Function <br />58 Display Software Revision <br />64 Print Set-up Values <br />65 Enter No. of Contacts <br />66 Display Contact Status <br />67 Set Probe Error Alarm Level <br />68 Manifold Tanks <br />69 Display Tank Information <br />70 Number of Tanks <br />71 Probe Entry <br />72 Initial Product (Gas) <br />73 Initial Product (Water) <br />74 Tank Type and Size <br />75 Leak Detect GPH Threshold <br />76 Hi Water Alarm Level <br />77 Linear Scale <br />78 Fuel Label <br />79 Theft Gallon Limit <br />80 Net to Gross Gallon <br />81 Relay #1 (Programmable) <br />82 Relay #2 (Programmable) <br />83 Relay #3 (Programmable) <br />84 Relay #4 (Programmable) <br />85 Start Leak/ Theft Detect (Manual) <br />86 Start Leak/Theft Detect (Manual) <br />87 Set-up Auto Leak Detect Mode <br />88 Enable and Disable Leak Detect Mode <br />89 Print Leak Detect Set-up Parameters <br />90 Time Entry <br />91 Date entry <br />93 U.S. Units to Metric <br />94 Station Name <br />95 Station Address <br />96 Station City and State <br />290 Begin Calibration and Programming Sequence <br />291 End Calibration and Programming Sequence <br />Table 6.1: Function Codes. <br />
The URL can be used to link to this page
Your browser does not support the video tag.