My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231489
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 12:48:49 PM
Creation date
11/7/2018 4:28:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0231489
PE
2381
FACILITY_ID
FA0000309
FACILITY_NAME
MCHENRY STATION & MINI MART
STREET_NUMBER
1405
STREET_NAME
MAIN
STREET_TYPE
ST
City
ESCALON
Zip
95320
CURRENT_STATUS
02
SITE_LOCATION
1405 MAIN ST
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\1405\PR0231489\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
8/10/2017 11:32:00 PM
QuestysRecordID
3570812
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATE OF CALIFORNIAO WATER RESOURCES CONTROL RD <br /> FORM `B': UNDERGROUNDMT APPLICATION INFORMATION <br /> TANK TANK PER <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACHTANK. <br /> `"66: " <br /> F-] 1 NEW PERMIT F--] 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> 10 <br /> MARK ONLY <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FARM TANK-YES❑ NO <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: f KLG A, <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> [C. <br /> EYEAR <br /> RS TANK ID# Q B. MANUFACTURED BY: 0 <br /> INSTALLED 1 (.� D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL2 PETROLEUM B. C, [:] 1 UNLEADED ❑ 2 LEADED El3 DIESEL <br /> F-] 3 CHEMICAL PRODUCT �4 OIL ❑ 1 PRODUCT El GASAHOL ❑ 5 JET FUEL ❑ 5 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY [:] 95 UNKNOWN 2 WASTE ❑ 7 METHANOL g99 OTHER(QESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF OIL- <br /> Ill. <br /> 11 L <br /> HAZARDOUS SUBSTANCE STORED&C A.S.# CEJ L <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C.&D <br /> A.TYPE OF ❑ I DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER5 UNKNOWN <br /> SYSTEM F-] 2 SINGLE WALLED F-] 4 SECONDARY CONTAINMENT 6199 OTHER <br /> ❑ 1 STEEL/IRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK F-1 5 CONCRETE El POLYVINYLCHLORIDE F] 7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRF <br /> MATERIAL <br /> ❑9 BRONZE F110 GALVANIZED STEEL UNKNOWN 99 OTHER <br /> ❑ 1 RUBBER LINED ❑2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> C. INTERIOR ❑5 GLASS LINING ❑ 6 UNLINED F�T%UNKNOWN <br /> LINING <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO 99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYLWRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NCNE A&5 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELIIRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PUC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A(D5 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S I VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 9 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P 5 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1_ ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3, WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? YES ❑ NO <br /> GALLONS <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> fPERMIT <br /> OUNTY# JURISDICTION# AGENCY* FACILITY ID# TANK ID# <br /> I ] � � � � 1041 <br /> NT LOCAL AGENCY FACILITY ID# <br /> APPROVED BY NAME PHONE#WITH AREA CODE <br /> \ s <br /> NUM$ERPERMIT APPROVAL DATE PERMIT EX ATION DATE <br /> # PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPA D BY A FACILITY/SITE APPLICATION, FORM 'A',UNLE IZ .URRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.