My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1515
>
2300 - Underground Storage Tank Program
>
PR0501179
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 12:52:43 PM
Creation date
11/7/2018 4:32:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0501179
PE
2381
FACILITY_ID
FA0009865
FACILITY_NAME
KIA COUNTRY
STREET_NUMBER
1515
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21619005
CURRENT_STATUS
02
SITE_LOCATION
1515 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\1515\PR0501179\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
10/26/2017 3:30:01 PM
QuestysRecordID
3700909
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFO&A WATER RESOURCES CO ROL BOARD <br /> FORM `B': UNDERGROUND STORAGE T, OGRAM ' <br /> TANK / TANK PERMIT APPLICATION INFORMATION m,w; <br /> L/ COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK.� - 'z <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK Ia <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> W <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: �/ a `- S f - n7 M TANK-YES '7❑ NO (� <br /> 1. TANKDESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY � <br /> O <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: -4 <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.7),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT 4 OIL VWASTE <br /> CT E] 4 GASAHOL ❑ 5 JET FUEL ❑ fi AVIATION GAS <br /> 5 HAZARDOUS 80 EMPTY 95UNKNOWN ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAMEi5F <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: 6 <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR UNE 5 UNKNOWN <br /> SYSTEM ❑2 SINGLEWALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEEUIRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 LUMINUM ❑8100%METHANOL COMPATIBLE FAP <br /> MATERIAL <br /> [:]9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN ❑99 OTHER <br /> C.INTERIOR <br /> ❑ 1 RUBBER LINED E] 2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 NOCK UNING <br /> LINING F-15 GLASS LINING ❑ 6 UNLINED 5 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 10096 METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ I POLYETHLENEWRAP ❑2 TAR OR ASPHALT 3y*L WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE IL=_-41'[ss UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IFABOVEGROUND, U IFUNDERGROUNO BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U i SUCTION A U 2 PRESSURE A U GRAVITY A U 91 NONE A U A U 99 OTHER <br /> B.CONSTRUCTION A U i SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U VIIUNKNOWA U 99 OTHER <br /> A U i STEEUIRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLADWYFRP A U 8100%METHANOL COMPATIBLE FRP <br /> A. U 9 GALVANIZED STEEL A 95 UN WN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 1VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 8 3VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P 6 PRECISION TESTING P 8 7 PRESSURETESTING P 8 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? E]YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> "APPLICANTS NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> C) / 3 G a <br /> CURRENT LOCAL AGENCY FACCIL'ITIY IDM APPROVED BY NAME PHONE#WITH AREA CODE <br /> IN <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# SY4 <br /> 1 a jAef- 's <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM `A',UNLESS A CURRENT FORM'A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />