My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
334
>
2300 - Underground Storage Tank Program
>
PR0231665
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 4:44:20 PM
Creation date
11/7/2018 4:53:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231665
PE
2361
FACILITY_ID
FA0003714
FACILITY_NAME
LACHHAR CHEVRON*
STREET_NUMBER
334
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
26115041
CURRENT_STATUS
02
SITE_LOCATION
334 E MAIN ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\334\PR0231665\BILLING 1985 - 2004.PDF
QuestysFileName
BILLING 1985 - 2004
QuestysRecordDate
3/3/2017 12:45:56 AM
QuestysRecordID
3347324
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• IED PROGRAM CONSOLIDATED FORM I � TANK: TA0505758 <br /> PR#: PR0231665 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 FAC#: FA0003714 <br /> (two pages per tank) <br /> Pope 2 of 7 <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Clxk only ima only) <br /> '. ❑ ]PERMANENTLY CLOSED ON SITE <br /> ❑ 3RENEWAL PERMIT (Spozifyrmast-forloaluscody) (Spxiyswson forlowti¢cony) ❑ 8TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: PRI;: 1 <br /> CHEVRON USA INC#91452"` 3 FA0003714 PR0231665 <br /> LOCATION WITHIN SITE(optimal) 334 E MAIN ST,RIPON 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted W the local agency.) <br /> TANK ID# Tank#: 6 432 TANK MANUFACTURER 413 COMPARTMENTALIZED TANK E]Yes 7LNo 434 <br /> TA0505758 XERXES If-Ya',amnPmemepaperoroachi mpanmml. <br /> DATE INSTALLED(YEAR/MO) q36 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 8/1/1995 12,000 <br /> ADDITIONAL DESCRIPTION(For kcal use Dory) 438 <br /> H.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 940 <br /> ® I.MOTOR VEHICLE FUEL ex..REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> 0rmakd mmpinc Pcwlam Type) *lb.PREMIUM UNLEADED [j3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ 1c.MIDGRADE UNLEADED ❑ 4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME uma,Naamo o Mamials Immm owe) 441CAS#(from Haamdous Ma mals nvm yPaB <br /> e) uz <br /> ❑ 4.HAZARDOUS WASTE <br /> 0xkmusmDa) 30CLO - <br /> [j95.UNKNOWN tai <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Clcakanc it.only) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIA.-primary lank ❑ 1.BARE STEEL M FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 444 <br /> (Chxkom itan only) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99,OTHER <br /> TANK MATERIAL-secondary tank ❑ LBARE STEEL 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check am item only) ❑ 2.STAINLESS STEEL ❑4.STEELCLADW/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ I.RUBBER LINED ❑ 3.EPDXY LINING44] <br /> OR COATING ❑ 5.GLASS LINING ❑95.UNKNOWN 44e DATE INSTALLED <br /> (Checkone irnmonly) ❑2 ALKYD LINING ❑ 4 PHENOLIC LINING ® 6 UNLINED ❑ 99.OTHER <br /> (Por Ixal me only) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (C6xkmmitmsmuy) ❑ 4 IMPRESSED CURRENT El 99 OTHER <br /> ❑ 25ACRIFICW.ANODE For local us<only) <br /> SPILL AND OVERFILLYEARINSTALLE450 TYPEdoalusemy) 451 OVERFILL PROTECTION EQUIPMENT:YEAR STALLED 452 <br /> (ChxkallWnappy) Ito I SPILL CONTAINMENT 1,995.00 ❑ 1ALARM opW UIL-C-),I/�IL�[TJ(�y.Bl $WIT FVAL` <br /> 2DROP TUBE ❑ 2BALL ❑ 4EXEhTRf 1 <br /> ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A ilmmpuoaorlhe manbaimpro mn shall In sabmiuW to as laod mcsiy) <br /> IF SINGLE WALL TANK(Claxk all thatapply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Chxk cane ucmaay) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> M 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR(MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />