Laserfiche WebLink
FIED PROGRAM CONSOLIDATED FORMqr TANK: TA0504864 <br /> • PR N: PR0231173 <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 FAC N: FA0006423 <br /> (two pages per tank) <br /> TYPE OF ACTION Page 6 of 7 <br /> (Chrek mlv item wdr) ❑ INEW SITE PERMIT ❑ 4AMENDED PERAUT ❑ 5CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT ISRh msson-Porinuhl me onl.l 15wnrcvwirorl-aluu anhl ❑ STANK REMOVED 430 <br /> BUSINESS NAME(5a .FACILDYNAMEor ,DBA-Win,Business\sl F.IC L Il IU. FR 1 <br /> UNITED GAS FA0006423 PR0231173 <br /> LOCATION WITHIN SITE(0,ocn I 3440 E MAIN ST,STOCKTON 431 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks sball be submitted to the local agency.) <br /> TANK IDN Tank#: 6 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK E] 1, ❑No 434 <br /> TA0504864 TRUSCO If"Y ,wmptac o«Pasc wrwm wmpnwwnt. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 10/21/1993 12:00:OOAM 10,000 <br /> ADDITIONAL DESCRIPTION(For loos wa my) 438 <br /> 11.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> M L MOTOR VEHICLE FUEL ® la REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> ufam wmpmw K,. i T.pe) ❑ Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑2.NON-FUEL PETROLEUM ❑ Ic.MIDGRADE UNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑3.CHEMICAL PRODUCT COMMON NAME ruw Harardow 14a i sSmwlwy w) 441 CAS#(nun Havdoaa M«cnaus w,,page) 442 <br /> ❑4.HAZARDOUS WASTE <br /> (bwludes Uxd q) <br /> ❑ 95.UNKNOWN <br /> IO.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Chea meiwm«dy) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-pnmary tank ❑ I.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Chale me item mit) ❑2.STAINLESS STEEL ® STEEL CLADW/FIBERGLASS ❑ 8.FRP COMPTIBLE W/I00%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN U5 <br /> (Clwkare iron way) ❑ 2.STAINLESS STEEL ®4.STEEL CLAD W/FIBERGLASS ❑ ,.FRPCOMPTIBLEW/100-/.METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ L RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (C7xrk om nan oNp) ❑2 ALKYD LINING ❑ 4 PHENOLIC LINING ® 6 UNLINED ❑ 99.OTHER <br /> (For1oW:¢ody) <br /> OTHERCORROSION ❑ I MANUFACTURING CATHODIC ❑ 3FIBERGLASSREINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Chale o«item mis) ❑ 4 IMPRESSED CURRENT ❑ 99 OTHER <br /> ❑2 SACRIFICIAL ANODE (For lod ore way) <br /> SPILL AND OVERFILL YEAR MSTALLE450 TYPE(1w.anly) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 432 <br /> (Chwknllthw V,K) ® I SPILL CONTAINMENT 1,993,00 ❑ IALARM ® 3 FILLTU13E SHUT OFF VAL` 1,993.00 <br /> Q 2 DROP TUBE 1,993.00 ❑ 2 BALL ❑ 4 EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A deanpum oftle mmiwdi,vmemm sUl be sub ni dwthewm a,4ary:) <br /> IF SINGLE WALL TAN K(Ch mlmss appy) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) ICnai:ane nan mIU) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ASG) ❑ 6VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ❑2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ STANKTESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 453 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑No <br /> UPCF(12/99 revised) <br />