Laserfiche WebLink
`SUM VERIFICATION LABORATORY A*YSIS <br /> TANK TANK TPH-G TPH-D BTX& E CL HC TOTAL MTBE METALS PCB <br /> CONTENTS 801 raA.Otee 8015 8020 8010 LEAD API 8270 <br /> 8260 8260 8260 8240 7420 TAME AES or 8080 <br /> 7421 AA <br /> 8260 <br /> LEADED GAS X X X X <br /> UNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X <br /> UNK FUEL X X X X X <br /> PROD. OIL X X <br /> CHLOR. <br /> SOLVENTS X X <br /> NONCHLOR <br /> SOLVENTS X X X <br /> USE O,II X X X rX I I X I X <br /> All analysis methods are the designated EPA methods described in EPA SW 846, Third Edition. Those methods not found in <br /> SW 846 are specifically noted below. Refer to the "SWRCB LUFI' Field Manual", Appendix D (B), Table 3-5 on page A20 <br /> for minimum detection limits for motor vehicle fuel (gasoline and diesel). Refer to 1-2-3 'Regional Board Staff <br /> Recommendations for Initial Evaluation and Investigation of UST's" for the waste and motor oil minimum detection limits. <br /> Detection Limits that remain below the MCL, STLC or Allowable Limit of the contaminant in question will be accepted, <br /> however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon, Gasoline, GC/FID (5030) 8015 mod or GC/MS 3260 <br /> TPH-D Total Petroleum Hydrocarbon. Diesel, GC,'FID (3550), 8015 mod or GC/MS 3260 <br /> BTX & E Benzene, Toluene, Xylene &Ethyl Benzene, GC/PID 8020 or GC,'MS 8260 <br /> CL HC Chlorinated Hydrocarbon, GC/HSD 8010, GC/MS 8240 <br /> TOTAL LEAD Total lead, AA 7420, AA 7421 or ICP-AES 6010 <br /> MTBE Methyl Tertiary Buryl Ether, GCNS 8260 <br /> METALS ICAP or AA huiucdveiy Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption <br /> Spectrometry 7000. Metals: Cadmium, Chromium III and VI, Lead, Zinc and Nickel. <br /> PCB Polychlorinated Biphenyls, GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography, Flame Ionization Detection <br /> Method 3050 Add digesdon <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation, extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quatiry Control <br /> Notes: To avoid false positive detection of benzene, benzene-fiu solvents are to be used. Fused capillary rnlumns are <br /> preferred to packed columns; a packed column may be used as a 'first cut" with 'dim" samples or once the hydrocarbons have <br /> been characterized and proper QA/QC is followed. <br /> For drinking water sources, EPA recommends that the 500 series for volatile organic should be used in preference to the 600 <br /> series because the detection limits are lower and the QA/QC is better_ Samples exhibiting any level of heavy metal <br /> contamination may require further analysis. PHS-EHD recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 10/24/97) Page 8 <br />