Laserfiche WebLink
UIVIrlt1J rKvljKAIVl L_UIV0VL1lI I Cu rUrtivl U\ <br />TANKS <br />UNDERAPbUND STORAGE TANKS -- *K PAGE 1 <br />( uL (two pages per tank) <br />Page _ of _ <br />TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br />(Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br />® 3 RENEWAL PERMIT (Specify reason -for local use only) (Specify reason -for local use only) ❑ 8 TANK REMOVED 430 <br />USINESS NAME (Same as FACILITY NAME or DBA- Doing Business As) <br />BF <br />FACILITY IQ: <br />1 <br />Beacon Station #3492 <br />3 <br />Tpt <br />O <br />© <br />C2 <br />(-� <br />fl <br />LOCATION WITHIN SITE (optional) 431 <br />I. TANK DESCRIPTION (A scaled plat plan with the location of the UST system including buildings and landmarks shall be submitted to the local <br />agency.) <br />TANK ID # tp 432 <br />TANK MANUFACTURER 433 <br />COMPARTMENTALIZED TANK (] Yes ® No 434 <br />3492-2 TAoQ <br />Trusco <br />If "Yes', complete one page for each compartment. <br />DATE INSTALLED (YEARIMO) 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS 437 <br />12198 <br />14000 <br />1 <br />ADDITIONAL DESCRIPTION (For local use only) 438 <br />IL TANK CONTENTS <br />TANK USE 439 <br />PETROLEUM TYPE 44C <br />1. MOTOR VEHICLE FUEL <br />❑ la. REGULAR UNLEADED ❑ 2. LEADED [35. JET FUEL <br />If marked complete Petroleum Type) <br />® III PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br />❑ 2. NON -FUEL PETROLEUM <br />❑ 1c. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑ 99. OTHER <br />[13. CHEMICAL PRODUCT <br />COMMON NAME (from Hazardous Materials Inventory page) 441 <br />CAS# (from Hazardous Materials Inventory page) 442 <br />❑ 4. HAZARDOUS WASTE <br />8006-61-9 <br />(Includes Used Oil) <br />❑ 95. UNKNOWN <br />Ill. TANK CONSTRUCTION <br />TYPE OF TANK Ell. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br />(Check one item only) EXTERIOR MEMBRANE LINER [195. UNKNOWN <br />® 2. DOUBLE WALL ❑ 4. SIGNLE WALL IN VAULT ❑ 99. OTHER <br />TANK MATERIAL -primary tank ® 1. BARE STEEL [13. FIBERGLASS / PLASTIC El5. CONCRETE [:195. UNKNOWN 444 <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 8. FRF COMPATIBLE WI ❑ 99. OTHER <br />REINFORCED PLASTIC (FRP) 100% METHANOL <br />TANK MATERIAL-secondarytank ❑ 1. BARE STEEL 3. FIBERGLASS /PLASTIC Cl 5. CONCRETE [195, UNKNOWN 445 <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD WIFIBERGLASS ❑ 8. FRP COMPATIBLE ❑ 99. OTHER <br />REINFORCED PLASTIC (FRP) W/100% METHANOL <br />❑ 5. CONCRETE ❑ 10. COATED STEEL <br />TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑i 5. GLASS LINING ❑ 95. UNKNOWN 446 DATE INSTALLED 447 <br />OR COATING ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING Z 6 UNLINED ❑ 99 OTHER <br />(Check one item only) (For local use only) <br />448 DATE INSTALLED 449 <br />OTHER CORROSION ❑ 1 MANUFACTURED CATHODIC ❑ 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN <br />PROTECTION IF APPLICABLE PROTECTION ❑ 4 IMPRESSED CURRENT D 99 OTHER <br />(Check one item only) ❑ 2 SACRIFICIAL ANODE (For local use only) <br />SPILL AND OVERFILL YEAR INSTALLED 450 TYPE (local use only) 451 <br />OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br />(Check all ® 1 SPILL CONTAINMENT <br />1998 <br />® I ALARM ❑ 3 FILL TUBE SHUT OFF VALVE <br />that apply} <br />® 2 DROP TUBE 1998 <br />❑ 2 BALL FLOAT ❑ 4 EXEMPT <br />® 3 STRIKER PLATE 1998 <br />IV. TANK LEAK DETECTION (A description of the monitoring program shall be submitted to the local agency-} <br />IF SINGLE WALL TANK (Check all that apply) 453 <br />IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br />(Check one iters only) <br />❑ 1 VISUAL (EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING (MTG) <br />❑ 1 VISUAL (SINGLE WALL IN VAULT ONLY) <br />❑ 2 AUTOMATIC TANK GAUGING (ATG) ❑ 6 VADOSE ZONE <br />® 2 CONTINUOUS INTERSTITIAL MONITORING <br />❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER <br />❑ 3 MANUAL MONITORING <br />❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING <br />+ (SIR) BIENNIAL TANK TESTING [:199 OTHER <br />IV. TANK CLOSURE INFORMATION ! PERMANENT CLOSURE IN PLACE <br />ESTIMATED DATE LAST USED (YRIMOIDAY) 455 <br />ESTIMATED QUANTITY OF SUBSTANCE 458457 <br />TANK FILLED WITH INERT MATERIAL? <br />REMAINING <br />gallons <br />® Yes d No <br />UPCF (1/99 revised) Formerly SWRCB Form B <br />