Laserfiche WebLink
a <br /> aoARD of TRUSTEES SAN JOAQUIN LOCAL HEALTH DISTRICT S€RVINQ <br /> Jamas Culbertson, Pres. I City of Lodi <br /> Patricia E. Vannuccl, sec•y. 1641 East Hazelton Avenue P. 0. Box 2069 San Joaquin County <br /> Anthonelte Van Spronsen City of Escalon <br /> Earl Plmentel Stockton, California 95201 City of Manteca <br /> Fern Bugbea 209/466-6781 City of Ripon <br /> Daniel L. Flores City of Stockton <br /> John 0. Mast, M.D. City of Tracy <br /> William J. Wade Jogi Khanna, M.D., M.P.H., District Health Officer San Joaquin County <br /> Mary Anna Love 5r[1ee San Joaquin County <br /> Facility Name <br /> Address <br /> Date of Inspection -7--q Inspector <br /> MONITORING ALTERNATIVE ,#7 <br /> Limited to undernround storage tanks which have infrequent inputs and withdrawals and <br /> where the liqui(: level in the tank can be measured to an accuracy of +5 gallons or less <br /> when the tank is half full . <br /> This onitoring alternative shall include: <br /> Annual precision test on tank and piping. <br /> VTank gauging performed as follows: <br /> Tank must be capable of being secured to prevent unauthorized inputs and <br /> withdrawals. <br /> Tank must have no inputs or withdrawals for at least a 48 hour period <br /> (.2 days) at the end of consecutive periods lasting up to 7 days. <br /> (For example: tank in use Monday through Friday, then locked <br /> over weekend) . <br /> Liquid level measurements are taken at the beginning and end of the <br /> monitoring period (lasting at least 48 hours) . <br /> (For example: level measured and recorded Friday night before <br /> locking and again on Monday morning before opening. ) <br /> If liquid level varies more than 1% of the tank volume or 5 gallons, which <br /> ever is less , between measurements , an unauthorized release shall be <br /> assumed to have occurred and shall be reported to the local agency within <br /> 24 hours, as per Article 5, Sect. 2652 of the regulations and further <br /> evaluations shall be performed to verify or disprove the variations. <br /> Implementation of the monitoring alternative requires that the following circled items be <br /> completed by the dates specified. <br /> 1 . Precision test(s) must be performed by �q-� —9.7nd results submitted to this <br /> office within 30 days of the test. <br /> O2. Tnk gauging must be started immediately. (See instructions above), <br /> If the above compliance dates cannot be met, contact this office prior to the specified <br /> date. <br /> 4/86 UGT 3 <br />