Laserfiche WebLink
ENVIRONMENTAL HEALTAEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> Donna K.Heran,RE.H.S. Unit Supervisors <br /> Director 304 East Weber Avenue, Third Floor Carl Borgman,R.E.H.S. <br /> At Olsen,R.E.H.S. Stockton, California 95202-2708 Mike Huggins,Wilson, <br /> S.,R.D.I. <br /> • 6 . "P • <br /> Program Manager Douglas W.Wilco,R.E.H.S. <br /> '°tikd"aa� Laurie Cotulla,R.E.H.S. Telephone: (209) 468-3420 Margaret Lagorio,R.E.H.S. <br /> Program Manager Fax: (209) 464-0138 Robert McClellon,R.E.H.S. <br /> Mark Barcellos,R.E.H.S. <br /> May 16,2005 <br /> Valued Engineering <br /> 1659 Lucerne Ave <br /> Stockton CA 95203 <br /> RE: Manteca Liquor and Food,890 N.Main St.,Manteca CA <br /> The San Joaquin County Environmental Health Department(SJCEHD)has received the <br /> permit to replace a existing spill bucket and install a mechanical leak detector on the premium <br /> (9 1)underground storage tank at the above referenced location. The permit has been <br /> approved with the following conditions: <br /> 1. Contact the local fire department, and the San Joaquin Valley Air Pollution Control <br /> District for applicable permits and requirements. <br /> 2. Any changes in information or scope of work must be submitted to SJCEHD prior to <br /> commencing work. <br /> 3. At least one person who holds the International Code Council"UST <br /> Installer/Retrofitter"certification must be onsite AT ALL TIMES when work is <br /> performed. <br /> 4. A"Certificate of Compliance for Underground Storage Tank Installation Form C" <br /> shall be submitted by the owner or the owners'agent [pursuant to California Code of <br /> Regulation(CCR)2635(d)]before this upgrade will be considered complete by <br /> SJCEHD. <br /> 5. Contact Ray von Flue at(209)468-9848 to arrange the following inspection <br /> appointments; a 48-hour notice for inspection appointments is required. <br /> a. Corrosion protection:prior to backfilling around the spill buckets,corrosion <br /> protection of the risers must be verified. <br /> b. Overfill prevention: overfill prevention system in compliance with CCR 2635 <br /> (b)(2)must be verified. If old drop tube is used this is not applicable. <br /> c. Spill Bucket: after concrete is poured,verify minimum 5-gallon capacity and <br /> conduct a 30-minute lake test in compliance with CCR 2635(b)(1). Proper <br /> drainage must also be verified. <br /> d. Third party tank integrity test must be performed once concrete is poured, <br /> prior to the contractor signing off of the jobsite. The test results must be <br /> submitted to SJCEHD within 7 days of completing this project. <br /> e. Three gallon per hour leak test must be performed on the new mechanical line <br /> leak detector. <br /> 6. Permit expires 90 days from the approval date. Note: if an extension to the <br /> expiration date is required,this office prior to the expiration date must receive a <br /> written request. <br /> Thank you, <br /> Raymond von Flue, REHS <br /> San Joaquin County <br /> Environmental Health Department <br />