Laserfiche WebLink
Appendix VI MAY 10 2016 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California EIVVIRON1 �T <br /> Authority Cited:Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of F%"i k HEALTF{ <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for tttROCES <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Manteca Liquor Food Bldg.No.: <br /> Site Address: 890 N MAIN ST City: MANTECA CA Zip: 95336 <br /> Facility Contact <br /> Pe nn JEET Contact Phone No.: (209)765.2619 <br /> 418-2016 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment ins ectecilserviced: <br /> Tank ID: 87 OCT Tank ID: 91 OCT <br /> N In-Tank Gauging Probe. Model: MAG 1 N In-Tank Gauging Probe. Model: MAG 1 <br /> N Annular Space or Vault Sensor. Model: 420 N Annular Space or Vault Sensor. Model: 420 <br /> N Piping Sump/Trench Sensor(s). Model: 208 N Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> N Mechanical Line Leak Detector. Model: FXIX N Mechanical Line Leak Detector. Model: FE PETRO <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overall/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DSL Tank ID: <br /> N In-Tank Gauging Probe. Model: MAG 1 ❑ In-Tank Gauging Probe. Model: <br /> N Annular Space or Vault Sensor. Model: 420 ❑ Annular Space or Vault Sensor. Model: <br /> N Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> N Mechanical Line Leak Detector. Model: FXIV D ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1.2 Dispenser ID: <br /> N Dispenser Containment Sensor(s). Model: 208 ❑ Dispenser Containment Sensor(s). Model: <br /> N Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Cham(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 3-4 Dispenser ID: <br /> N Dispenser Containment Sensor(s). Model: 208 ❑ Dispenser Containment Sensor(s). Model: <br /> N Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): N System set-up N Alarm history report <br /> Technician Name(print): DAVE WINKLER Signature: V-a'-__j' <br /> Certification No.: 5263373-UT License No: 08-1739 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2n0 STREET GALT,CA 95632 Date of Testing/Servicing: 4-18-2016 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br /> SSC <br />