My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
890
>
2300 - Underground Storage Tank Program
>
PR0231984
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/17/2022 4:12:56 PM
Creation date
11/7/2018 5:37:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231984
PE
2361
FACILITY_ID
FA0001393
FACILITY_NAME
MANTECA LIQUOR & FOOD
STREET_NUMBER
890
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22302007
CURRENT_STATUS
01
SITE_LOCATION
890 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\890\PR0231984\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
3/1/2017 7:11:38 PM
QuestysRecordID
3346092
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siqov.orq/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MANTECA LIQUOR& FOOD 890 N MAIN ST MANTECA Aril 24 2017 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status o V o R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V c R o COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V o R o COS <br /> 325 CCR 2717.1(0 Deposited petroleum into a red tagged UST o V in R o COS <br /> 326 HSC 25291 Tampered with or disabled leak detection devices or alarms o V o R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V c R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V o R a COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements o V o R o COS <br /> 330 CCR 2636(0(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V i R o COS <br /> Single-Walled Non-Pressurized Piping W �re;zpaa <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V a R o COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V o R o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1964) o V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V o R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation o V o R o COS <br /> 2060 See below Unlisted Design/Construction violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS It,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> The Letter from Chief Financial Officer document in CERS does not have the correct tank address.Also, a current <br /> financial responsibility document for 2017 has not been submitted to CERS. Current financial responsibility <br /> documents are required to be submitted annually. Immediately log into the California Environmental Reporting System <br /> (CERS)at http://cers..calepa.ca.gov/, and upload the required documents. <br /> This is a repeat violation, Class ll. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The site map is missing the location of the leak detectors <br /> for all three tanks. A site plan must be submitted identifying the locations where monitoring will be performed. <br /> Immediately log into the California Environmental Reporting System(CERS)at http://cers.calepa.ca.gov/and upload a <br /> copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> Page 3 of 4 <br />
The URL can be used to link to this page