COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
890
>
2300 - Underground Storage Tank Program
>
PR0231984
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/17/2022 4:12:56 PM
Creation date
11/7/2018 5:37:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231984
PE
2361
FACILITY_ID
FA0001393
FACILITY_NAME
MANTECA LIQUOR & FOOD
STREET_NUMBER
890
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22302007
CURRENT_STATUS
01
SITE_LOCATION
890 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\890\PR0231984\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
3/1/2017 7:11:38 PM
QuestysRecordID
3346092
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.oro/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> MANTECA LIQUOR&FOOD (209)239-4550 April 16, 2018 <br /> Facility Address: CERS ID: <br /> 890 N MAIN ST, MANTECA, CA 95336 10180741 <br /> Inspection ContactTitle: Phone: <br /> Gurenderjeet Sandhu Owner (209)499-1721 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For. Consent Given By: <br /> O Inspection 9 Photos O Samples Gu renderjeet Sandhu, Owner <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> David Winkler 01/29/2020 Alex Jabbari 10/03/2018 <br /> Service Technician Manufacturer's Training: <br /> VMI, 11102/19; Veeder Root, 02/28/20; Tank Tester, 03/31/20 <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeal violation COS=Conected on site during inspection <br /> File Review - <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHO including but not limited to unpaid fees o V o R c COS <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system o V in R o COS <br /> 103 HSC 25292,2,25299.30 Current financial responsibility documents not submitted o V o R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current o V o R o COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan is V is R o COS <br /> 2634(d) <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan in V in R o COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed •V •R in COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V o R o COS <br /> 109 CCR 2637 Failed to test secondary containment o V o R o COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days in V in R o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually o V in R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V o R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days o V o R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down in V o R in COS <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change w/iin 30 days in V o R in COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC cert nation o V o R o COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V o R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests o V o R a COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented o V o R in COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification in V o R in COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report a V in R a COS <br /> 122 CCR 2631 Q) Failure to submit and maintain UST system component statement of compatibility for substance stored o V o R o COS <br /> On Site Records <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records oV o R COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records an site for at least 6 1/2 years a V o R o COS <br /> FA0001393 PRO2319M SC001 04/1642018 <br /> EHD 23-01 Rev.09/22/16 Pagel of 4 Underground Storage Tank Program OR <br />
The URL can be used to link to this page
Your browser does not support the video tag.