My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231489
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 12:50:11 PM
Creation date
11/7/2018 5:45:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0231489
PE
2381
FACILITY_ID
FA0000309
FACILITY_NAME
MCHENRY STATION & MINI MART
STREET_NUMBER
1405
STREET_NAME
MAIN
STREET_TYPE
ST
City
ESCALON
Zip
95320
CURRENT_STATUS
02
SITE_LOCATION
1405 MAIN ST
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\M\MAIN\1405\PR0231489\COMPLIANCE INFO .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f __.. <br />September 27, 1988 C0016 u <br />Victor Farhoud <br />EZ Gas Minimart <br />1405 Main Street <br />Escalon, CA 95352 <br />Re: 1405 Main Street, Escalon <br />Review of the Supplemental Site Assessment submitted to this <br />office on 8 September 1988, reveals the following: <br />1. The SdLHD does not concur with the conclusions and recommend- <br />ations of the ETS Environmental report. Specifically: <br />a)The report does not include a cross-sectional diagram <br />indicating the direction and true vertical depth of the <br />30 degree angle borings #6 and #7, nor the relationship <br />of these borings to potential sources of the contamination <br />noted in boring #6. <br />b)lt is unclear from the information provided how the <br />analytical laboratory is able to distinguish between <br />"weathered" gasoline and diesel in characterizing the <br />contamination identified in the initial report. <br />c)The investigation does not address the diesel tank precision <br />test in 1986 which failed to show piping integrity and <br />the subsequent piping repair performed by R&R Service <br />Station Repair. <br />2. Further investigation may be required in the future to <br />identify the nature and extent of soil contamination noted <br />in the Preliminary Site Assessment Report of 7/11/88, and <br />to prove that groundwater contamination has not occurred <br />at this site. <br />3. An Unauthorized Release Report will be filed for this facility <br />and it will be added to the list of sites with evidence of <br />soil contamination. <br />Administration Clinical Services Environmental Health <br />468-3400 468-3830 468-3420 <br />Air Pollution Community Services Laboratory <br />468-3470 468-3820 468-3460 <br />AIDS Information 468-3820 <br />Public Health Nursing <br />468-3860 <br />WIC <br />468-3280 <br />HEALTH DiMICT <br />;Fln OF TRUSTEES <br />JOAQUIN LOCAL <br />SERVING <br />All Crow, Pres. <br />San Joaquin County <br />Earl Pimentel, Vice Pres. <br />1601 East Hazelton Avenue <br />City of Manteca <br />Tommy Joyce, Sec'y. <br />Stockton, California 95205 <br />City of Escalon <br />James F. Culbertson <br />City of Lodi <br />John D. Mast, M.D. <br />JOGI KHANNA, M.D., M.P.H., DISTRICT HEALTH OFFICER <br />City of Tracy <br />Virginia Mathews <br />City of Ripon <br />Thomas Schubert, D.V.M. <br />San Joaquin County <br />Daphne Shaw <br />City of Stockton <br />Harvey Williams. Ph.D. <br />San Joaquin County <br />f __.. <br />September 27, 1988 C0016 u <br />Victor Farhoud <br />EZ Gas Minimart <br />1405 Main Street <br />Escalon, CA 95352 <br />Re: 1405 Main Street, Escalon <br />Review of the Supplemental Site Assessment submitted to this <br />office on 8 September 1988, reveals the following: <br />1. The SdLHD does not concur with the conclusions and recommend- <br />ations of the ETS Environmental report. Specifically: <br />a)The report does not include a cross-sectional diagram <br />indicating the direction and true vertical depth of the <br />30 degree angle borings #6 and #7, nor the relationship <br />of these borings to potential sources of the contamination <br />noted in boring #6. <br />b)lt is unclear from the information provided how the <br />analytical laboratory is able to distinguish between <br />"weathered" gasoline and diesel in characterizing the <br />contamination identified in the initial report. <br />c)The investigation does not address the diesel tank precision <br />test in 1986 which failed to show piping integrity and <br />the subsequent piping repair performed by R&R Service <br />Station Repair. <br />2. Further investigation may be required in the future to <br />identify the nature and extent of soil contamination noted <br />in the Preliminary Site Assessment Report of 7/11/88, and <br />to prove that groundwater contamination has not occurred <br />at this site. <br />3. An Unauthorized Release Report will be filed for this facility <br />and it will be added to the list of sites with evidence of <br />soil contamination. <br />Administration Clinical Services Environmental Health <br />468-3400 468-3830 468-3420 <br />Air Pollution Community Services Laboratory <br />468-3470 468-3820 468-3460 <br />AIDS Information 468-3820 <br />Public Health Nursing <br />468-3860 <br />WIC <br />468-3280 <br />