Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton,California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:v .sioov.ora/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JAMAR SERVICE 4075 E MAIN ST STOCKTON 23, 2016 <br /> UST System Observations <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump o V o R o COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed o V o R o COS <br /> 323 CCR 2536(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi o V o R o COS <br /> 324 CCR 2635(b) No spill bucket installed orfailed to provide a means to keep it empty o V o R o COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons o V o R o COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements o V o R o COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden o V in R o COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status o V o R o COS <br /> 329 CCR 2717.1(8) Tampered with red tag n V o R o COS <br /> 330 CCR 2717.1 If) Deposited petroleum into a red tagged UST o V o R o COS <br /> 331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms n V o R o COS <br /> 332 CCR 2631.1 UST system not compatible with the substance stored o V o R o COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements o V o R o COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements o V o R o COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V o R o COS <br /> 402 CCR 2643(d) Dally monitoring of suction pipe(pre-Jan 1984)not performed o V o R o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping net performed(pre-January 1984) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V o R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation c V o R o COS <br /> 2060 See below Unlisted Design/Construction violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS It,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> Page 3 of 7 <br />