My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4075
>
2300 - Underground Storage Tank Program
>
PR0231667
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2019 4:22:44 PM
Creation date
11/7/2018 5:51:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0231667
PE
2361
FACILITY_ID
FA0002121
FACILITY_NAME
JAMAR SERVICE
STREET_NUMBER
4075
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
15726411
CURRENT_STATUS
01
SITE_LOCATION
4075 E MAIN ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\IAError\M\MAIN\4075\PR0231667\COMPLIANCE INFO 2016-PRESENT .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix A JUN 21 2016 <br /> MONITORING SYSTEM CERTIFICATION r'"Oei <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code;Chapter 16, Division 3,Title 23,California Code of Regulations' ` <br /> This form must be used to document testing and servicing of monitanng equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: JAMAR SVC Bldg.No.: <br /> Site Address: 4075 EAST MAIN STREET City: STOCKTON Zip: <br /> Facility Contact Person: JASON Contact Phone No.: (209)462-0685 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 6123/2016 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicateSpecific equipment ins ectad/serviced: <br /> Tank ID: 87 Tank ID: 91 <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> ® Annular Space or Vault Sensor. Model: 409 ® Annular Space or Vault Sensor. Model: SPILT/87 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sansone). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: PE PETRO ® Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill I High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> TanklD: TanklD: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(s). Model: ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor($). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> DispenserlD: 1.2 DispenserlD: 34 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> E9 Shear Velvets). ® Shear Valve(s). <br /> ® Dispenser Containment Float(s)and Chain(s). ® Dispenser Containment Float(s)and Chain(s). <br /> DispenserlD: 5.6 Dispenser ID: 7.8 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ® Dispenser Containment Float(s)and Chain(s). ® Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains mora tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment Identified 1n this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is Information(e.g.manufacturers'checklists)necessary to verify that this information Is correct <br /> and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply'): ®System set-up ®Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: '14111 �-� <br /> Certification No.: 834976 License No: 552737934-UTA 08-1740 OTTL <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2nd STREET GALT,CA 95632 Date of Testing/Servicing: 05-23-16 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />