BILLING 2003 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2132
>
2300 - Underground Storage Tank Program
>
PR0231669
>
BILLING 2003 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 3:48:51 PM
Creation date
11/7/2018 6:25:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2003 - 2007
RECORD_ID
PR0231669
PE
2361
FACILITY_ID
FA0001480
FACILITY_NAME
TESORO (MOBIL) 68222
STREET_NUMBER
2132
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17306035
CURRENT_STATUS
01
SITE_LOCATION
2132 MARIPOSA RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MARIPOSA\2132\PR0231669\BILLING\BILLING 2003 - 2007.PDF
QuestysFileName
BILLING 2003 - 2007
QuestysRecordDate
6/16/2016 8:47:50 PM
QuestysRecordID
3117329
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM (UP) FORM <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(Check all that apply) Page of <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ®1.PRESSURE 0 2.SUCTION O3.GRAVITY 458 0 1.PRESSURE 0 2. SUCTION 0 3.GRAVITY 459 <br /> CONSTRUCTION 0 1.SINGLE WALL 0 3.LINED TRENCH 099.OTHER 460 [11.SINGLE WALL 0 95.UNKNOWN 462 <br /> MANUFACTURER®2.DOUBLE WALL [195.UNKNOWN 0 2.DOUBLE WALL 0 99.OTHER <br /> MANUFACTURER J I r 461 MANUFACTURER 463 <br /> MATERIALS AND 0 1 BARE STEEL ❑6.FRP COMPATIBLE W/100%CORROSION METHANOL 01 BARE STEEL 0 6.FRP COMPATIBLE W/100%METHANOL <br /> PROTECTION 0 2.STAINLESS STEEL 0 7.GALVANIZED STEEL O2.STAINLESS STEEL 0 7.GALVANIZED STEEL <br /> 0 95.UNKNOWN <br /> 0 3.PLASTIC COMPATIBLE W/CONTENTS 0 8.FLEXIBLE(HDPE) O3.PLASTIC COMPATIBLE 0 g FLEXIBLE(HDPE)0 95.UNKNOWN <br /> W/CONTENTS <br /> 0 4.FIBERGLASS 0 9.CATHODIC PROTECTION 0 4. FIBERGLASS 0 9.CATHODIC PROTECTION <br /> [15.STEEL W/COATING 0 99.OTHER 464 [15. STEEL W/COATING 0 99. OTHER 465 <br /> VII.PIPING LEAK DETECTION(Check an that apps )(A description of the monitoeng program shell be submitted to the local a <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 0 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP 0 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST WITH AUTO PUMP <br /> SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM <br /> DISCONNECTION+AUDIBLE AND VISUAL ALARMS. DISCONNECTION+AUDIBLE AND VISUAL ALARMS. <br /> 0 2.MONTHLY 0.2 GPH TEST 02. MONTHLY 0.2 GPH TEST <br /> 0 3.ANNUAL INTEGRITY TEST(0.1 GPH) 0 3.ANNUAL INTEGRITY TEST(0.1 GPH) 0 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS(Check all that apply) CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> 0 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING 0 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) <br /> 0 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> 0 7.SELF MONITORING 0 7. SELF MONITORING <br /> GRAVITY FLOW GRAVITY FLOW(Check all Mat apply): <br /> 0 9.BIENNIAL INTEGRITY TEST(0.1 GPH) 08.DAILY VISUAL MONITORING 09.BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> ❑a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS 0 a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ®b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND 0 b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> SYSTEM DISCONNECTION DISCONNECTION <br /> Oc. NO AUTO PUMP SHUT OFF Oc NO AUTO PUMP SHUT OFF <br /> 11. AUTOMATIC LEAK DETECTOR(3.0 GPH TEST) 16MFLOW SHUT OFF 0 11. AUTOMATIC LEAK DETECTOR <br /> 012. ANNUAL INTEGRITY TEST(0.1 GPH) 012. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> 013. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS 013. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> 0 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF0 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF' <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> 0 15. AUTOMATIC LEAK DETECTOR(3.0 GPH)WITHOUT FLOW SHUT OFF [116. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> 0 16.ANNUAL INTEGRITY TEST(0.1 GPH) 0 17. DAILY VISUAL CHECK 0 16.ANNUAL INTEGRITY TEST(0.1 GPH) 0 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT 0 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE 0 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 0 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS 0 5.TRENCH LINER/MONITORING <br /> 0 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR 0 6.NONE 469 <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify Met the information provided herein is We and acourete to the best of my knowledge. <br /> SIGNATURE OF OWNER/ P R DATE 470 <br /> III ♦ L( -? --d <br /> NAME OF OW14E ' t) •• Tof <br /> ITLE OF OWNER/OPERATOR 472 <br /> Cynthia H Wrl General Mana er, Retail Services <br /> OFFICIAL USE ONLY Permit Number 473 1 Permit Approved 474 1 Permit Expiration Date 475 <br /> UP FORM(1/2000 Version) 3 Formerly SWRCB Form B <br /> SBC UST-B.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.