My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2002 INSTALL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
2467
>
2300 - Underground Storage Tank Program
>
PR0231818
>
INSTALL 2002 INSTALL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:57 PM
Creation date
11/7/2018 6:28:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2002 INSTALL
RECORD_ID
PR0231818
PE
2361
FACILITY_ID
FA0022456
FACILITY_NAME
Foodliner, Inc.
STREET_NUMBER
2467
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
Rd
City
Stockton
Zip
95205
APN
17130003
CURRENT_STATUS
02
SITE_LOCATION
2467 E Mariposa Rd
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MARIPOSA\2467\PR0231818\2002 INSTALL.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California Edition:June 1999 <br /> INCON Intelligent Controls,Inc. <br /> TS 1000/1001/2001 <br /> Incon LL2 Magnetostrictive Probe <br /> AUTOMATIC TANK GAUGING SYSTEM <br /> Certification: Leak rate of 0.2 gallons per hour with Pd=95.7%and Pfa=4.3%. <br /> Leak Threshold: 0.1 gph. A system should not be declared tight if the test result indicates a loss or gain that <br /> equals or exceeds this threshold. <br /> Applicability: Gasoline,diesel,aviation fuel and fuel oil#4. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Capacity: Maximum o00,000 gallons. <br /> Tanks less than 95%full may be tested. <br /> Minimum product level required based on tank diameter as follows: <br /> 48"dia/min 12";64"dia/min 14";72"dia/min 15";96"dia/min 17.5'; 126"dia/min.21.5". <br /> Waiting Time: Minimum of 4 hours 9 minute between delivery and testing. <br /> Minimum of 2 hours between dispensing and testing. <br /> There must be no delivery during waiting time. <br /> Test Period The length of the test is determined automatically based on quality of test data. <br /> Average data collection time during the evaluation was 6 hours, 51 minutes. <br /> Test data is acquired and recorded by a computer. <br /> Leak rate is calculated from data determined to be valid by statistical analysis. <br /> There must be no dispensing or delivery during the test. <br /> Temperature: Probe contains 5 thermistors to monitor product temperature.At least one thermistor must be <br /> submerged in product during testing. <br /> Water Sensor: Must be used to detect water ingress. Minimum detectable water level in the tank is 0.208 <br /> inches. Minimum detectable water level change is 0.011 inch. <br /> Calibration: Thermistors and probe must be checked and calibrated in accordance with manufacturer's <br /> instructions. <br /> Comments: This equipment was not evaluated using manifolded tanks. <br /> Tests only the portion of the tank containing product. <br /> As the product level is lowered,the leak rate in a leaking tank decreases(lower head <br /> pressure). Consistent testing at low levels could allow a leak to remain undetected. <br /> EPA leak detection regulations require testing of the portion of the tank system which <br /> routinely contains product. TS 1000 and 1001 can support up to 4 tanks.TS200Ican <br /> support up to 8 tanks. <br /> California regulations require at least one test per month after <br /> routine product delivery or when the tank is filled to within 10% of <br /> the highest operating level during the previous month. <br /> INCON Intelligent Controls,Inc. Evaluator:Ken Wilcox Associates <br /> 74 Industrial Park Rd. Tel:(816)443-2494 <br /> Saco,ME 04072 <br /> Tel:(800)872-3455 Date of Evaluation:05/14/98 <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the <br /> method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br /> 152 <br />