My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1986-2000
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MCHENRY
>
19527
>
2300 - Underground Storage Tank Program
>
PR0502008
>
BILLING 1986-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 9:19:14 AM
Creation date
11/7/2018 6:50:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1986-2000
RECORD_ID
PR0502008
PE
2381
FACILITY_ID
FA0000352
FACILITY_NAME
HOGAN MFG INC
STREET_NUMBER
19527
Direction
S
STREET_NAME
MCHENRY
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
24714030
CURRENT_STATUS
02
SITE_LOCATION
19527 S MCHENRY AVE
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MCHENRY\19527\PR0502008\BILLING 1986-2000.PDF
QuestysFileName
BILLING 1986-2000
QuestysRecordDate
9/13/2017 4:19:02 PM
QuestysRecordID
3635023
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIS WATER RESOURCES CONTROSPARD w <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> 1 NEW PERMIT 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK 10 <br /> MARK ONLY ❑ ❑ ❑ <br /> ONE ITEM ❑2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE 8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: ig <br /> FARM TANK-YES❑ NO N <br /> I. TANKDESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY C4) <br /> A. OWNERS TANK ID# 060 Z I B. MANUFACTURED BY: CTT <br /> C. YEAR INSTALLED U TANK CAPACITY IN GALLONS: f <br /> II. TANK ONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED �LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C A.S.# A,, C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A TYPE OF ❑ I DOUBLE WALLED F-]3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> Eel'l STEEUIRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑ 5 CONCRETE ❑6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 A LINING ❑ 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> C <br /> LINING F-1 � ❑ 95 UNKNOWN <br /> 5 GLASS LINING 6 UNLINED <br /> ❑ ISLINING MATERIAL COMPATIBLEWITH100%METHANOL2 E]YES ❑ NO �990THER <br /> D.CORROSION ❑ i POLYETHLENE WRAP ❑ 2 ROR ASPHALT F__] 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APP ABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY 1 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH 91 NONE A U 95 UNKNOWN A 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 1 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMP BLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1VISUAL CHECK P S 2INVENTORY RECONCILIATION S 3VADOSEWELLS P S 4 ELECTRONO MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P 3 6 PRECISION TESTING P S 7 PRESSURE TESTING P 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 4ESTIATED DATE LAST UBED(MO/VR) 2. ESTM TED QUANTITY OF 3. WA ANK FILLED WITHSU NCE REMAINING INATERIAL? ❑YES ❑ NOOAILONSORM HAS BEEN COMPLETED UNDER PENAL fY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> 3 = 6 t Do 2 <br /> CURRENT LOCAL AGENCY FA LITYID APPROV BY ME <br /> PHONE N WITH AREA CODE <br /> PEFNIT NUMBER PERMIT APPROVAL DATE PERMIT tXPIRATI6MDA E <br /> CMECKN PERMIT AMOUNT SURCHARGE AMT. FEE CODE GEIPTN BY: <br /> FORM B(6-29-BB) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.