MCKINLEY
>
16888
>
2300 - Underground Storage Tank Program
>
PR0232523
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 3:29:57 PM
Creation date
11/7/2018 6:59:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232523
PE
2361
FACILITY_ID
FA0003833
STREET_NUMBER
16888
STREET_NAME
MCKINLEY
STREET_TYPE
Ave
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16888 McKinley Ave
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MCKINLEY\16888\PR0232523\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
3/15/2017 3:43:37 PM
QuestysRecordID
3353613
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • REFI ® <br /> Appendix VI OCT 13 2016 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,and CaUfpptia.Gode.cf.R eftA TH <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report mus M tiV I Tit <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided tot M ENT <br /> owner/operator.The owner/operator must submit a mpy of this forth to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: SUPER STORE Bldg.Nc.: <br /> Site Address: 16888 MCKINLEV AVE City: LATHROP Zip: 95330 <br /> Facility Contact Person: KEVIN Contact Phone No.: (209)8584384 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Dale of Tasting/Servicing: 10-07-16 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicatespecific a ui ment ins ected/serviced: <br /> Tank ID: —DIESEL 1 Tank ID: DIESEL <br /> N In-Tank Gauging Probe. Model: MAG 1 N In-Tank Gauging Probe. Model: MAG 1 <br /> N Annular Space or Vault Sensor. Model: 303 N Annular Space or Vault Sensor. Model: 303 <br /> N Piping Sump/Trench Sensor(s). Model: 208 N Piping Sump/Trench Sensogs). Model: 208 <br /> ❑ Fill Sump Sensogs). Model: ❑ Fill Sump Sensors). Model: <br /> N Mechanical Line Leak Detector. Model: 99 LD 2000 N Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> N Tank Overfill/High-Level Sensor. Model: FLAPPER N Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: WASTE OIL Tank ID: NEW OIL <br /> ❑ In-Tank Gauging Probe. Model, ❑ In-Tank Gauging Probe. Model: <br /> N Annular Space or Vault Sensor. Model: 303 N Annular Space or Vault Sensor. Model: 303 <br /> N Piping Sump/Trench Sensor(s). Model: 208 N Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> DlspenserlD: 1-2 Dispenser ID: 3-4 <br /> N Dispenser Containment Sensor(s). Model: 406 N Dispenser Containment Sensods). Madel: 406 <br /> N Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Flom(s)and Chain(s). ❑ Dispenser Containment Flaat(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shearvalve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Floats)and Chain(s). ❑ Dispenser Containment Floats)and Chain(s). <br /> `If the facility contains more tanks or dispensers,copy this forth. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is Information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): N System set-up N Alamt history report <br /> Technician Name(pent): FELIX RAMIREZ Signature: d r ` -__> <br /> Certlfcatron No.: 5273934-UT License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2n°STREET GALT,CA 95632 Date of Testing/Servicing: 10-0746 <br /> Monitoring System Certification Page 1 of 2/21/07 <br />