My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MCKINLEY
>
16888
>
2300 - Underground Storage Tank Program
>
PR0232523
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 3:29:57 PM
Creation date
11/7/2018 6:59:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232523
PE
2361
FACILITY_ID
FA0003833
STREET_NUMBER
16888
STREET_NAME
MCKINLEY
STREET_TYPE
Ave
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16888 McKinley Ave
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MCKINLEY\16888\PR0232523\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
3/15/2017 3:43:37 PM
QuestysRecordID
3353613
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.orp/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> Super Store Industries-Grocery Division (209)858-3365 October 06, 2017 <br /> Facility Address: CERS ID: <br /> 16888 McKinley Ave, Lathrop, CA 95330 10166883 <br /> Inspection Contact: Title: Phone: <br /> Scott Sommerfeld Facilities Manager (209) 858-3384 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For: Consent Given By: <br /> 0 Inspection Z Photos ® Samples Scott Sommerfeld, Facilities Manager <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Zane Nimmo 06/02/2019 Troy Embry 06/21/2018 <br /> Service Technician Manufacturer's Training: <br /> VMI, 01/08/19;Veeder Root, 09/28117;Tank Tester, 01/08/17 <br /> CCR=California Cade of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate u V ❑R ❑COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V ❑R u COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ❑V ❑R ❑COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current ■V ❑R ■COS <br /> 105 CGR 2632(d)(1) Failed to have an approved UST monitoring plan ■V ❑R ■COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan u V ❑R ❑COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed o V o R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V o R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment o V ❑R o COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V ❑R o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually o V u R in COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V o R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days o V o R o COS <br /> 114 CCR 26360 Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down o V o R o COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days c V o R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V ❑R o COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after in V in R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V ❑R ❑COS <br /> 119 HSC 25299 Documents were falsified or misrepresented ❑V n R ❑COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installaticn/Modification o V ❑R in COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V o R e COS <br /> 122 CCR 2631 Q) Failure to submit UST system component statement of compatibility for substance stored r❑V ❑R ❑COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions n V ❑R ❑COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 112 years ❑V ❑R ❑COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site ❑V ❑R ❑COS <br /> FA0003833 PRO232523 SC001 10106/2017 <br /> EHD 23-01 Rev.09122116 Pagel of 4 Underground'Storage Tank Program OIR <br /> 9171 9690 0935 0151 6821 14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.