Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.ssigov.orct/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Super Store Industries-Grocery Division 16888 McKinley Ave, Lathrop October 06, 2017 <br /> UST System Observations <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V o R o COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V o R o COS <br /> 327 CCR 2631.1 UST system not compatible with,the substance stored o V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements o V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements In lieu of a line leak detector for emergency generator tank system o V ❑R ❑COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(x)(3) Suction piping not properly sloped or incorrectly located check valve n V , R COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted DesignlConstructior viclaticr n V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms the both of the diesel tanks are not current in CERS. In the"Vent, Vapor Recovery <br /> (VR)and Riser/Fill Pipe Piping Construction"section under"Vapor Recovery Primary Containment"change <br /> "Fiberglass"to"None". Any change of information must be updated in CERS within 30 days of the changes. <br /> Immediately lag into CERS, update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. Under"Under Dispenser Containment(UDC) <br /> Monitoring" under"UDC Monitoring"change"Continuous"to"Standalone"and remove"UDC Panel Model#"and <br /> "UDC Panel Manufacturer". The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). Immediately log into CERS,make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> FA©003833 PRO232523 SCO01 10106/2017 <br /> EHD 23-01 Rev.09!22!16 Page 3 of 4 Underground Storage Tank Program OIR <br />