My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MICKE GROVE
>
11793
>
2300 - Underground Storage Tank Program
>
PR0503587
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 11:40:52 AM
Creation date
11/7/2018 7:12:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0503587
PE
2381
FACILITY_ID
FA0000287
FACILITY_NAME
SJC MICKE GROVE PARK
STREET_NUMBER
11793
Direction
N
STREET_NAME
MICKE GROVE
STREET_TYPE
RD
City
LODI
Zip
95240
CURRENT_STATUS
02
SITE_LOCATION
11793 N MICKE GROVE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MICKE GROVE\11793\PR0503587\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
10/9/2017 9:20:48 PM
QuestysRecordID
3671865
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI4a WATER RESOURCES CONTROWARD <br /> FORM 'B': UNDE ROUND STORAGE TANK PROGRAM .; <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑5 CHANGE OF INFORMATION ❑ 1 PE MANENTLY CLOSE <br /> 10 <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE TANK REMOVED O <br /> ❑ <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: FARM TANK-YES❑ NON <br /> N <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: <br /> 4E ZE� <br /> C.YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(At),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1 PRODUCT ❑4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑BO EMPTY ❑95 UNKNOWN ❑ 2 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF C.A.S.#: <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# <br /> Ill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF [:] 1 DO BLEWALLED ❑ 3 SINGLE WALLED WITH EXTERIOR UNER ❑95 UNKNOWN <br /> SYSTEM SING ALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> STEEL/IRON ❑2 STAINLESS STEEL ❑3 RBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑610D%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> ❑ 1 RUBBER LINED ❑!2,AIWDLINING ❑3 EPDXY UNING ❑4 PHENOLIC LINING <br /> C. INTERIOR ❑5 GLASSLINING LrI3 UNLINED ❑ 95 UNKNOWN <br /> LINING <br /> ❑IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ I POLYETHLENE WRAP ❑2 TAR SPHALT ❑3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION 1 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A e4 <br /> SINGLEWALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> IWAI(I P 8 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> ` P 8 6 PRECISION TESTING P S 7 PRESSURE TESTING 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN <br /> 011LLONS INERT MATERIAL? ❑YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK IO# <br /> [H � D 10 o <br /> CURRENT LOCAL AGENCY F CILITY ID* APPROVED BY NAME Q(v PHONE#WITH AREA CODE <br /> a ��G� <br /> PERMIT NUMB R PERMIT APPROVAL DATE PER TE%PIMTION DATE <br /> CHECK M PERMIT AMOUNT URCNARGE AMT. FEE CODE RECEIPT p BY: <br /> FORM B G-29-56) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SRE APPLICATION, FORM'A',UNLESS A MENT FORMA' HAS BEEN FILED <br /> `t, DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.