My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1995
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MINER
>
1950
>
2300 - Underground Storage Tank Program
>
PR0504240
>
INSTALL_1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2019 9:26:42 AM
Creation date
11/7/2018 7:19:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1995
RECORD_ID
PR0504240
PE
2361
FACILITY_ID
FA0006136
FACILITY_NAME
QUICK TRUCK REPAIR
STREET_NUMBER
1950
Direction
E
STREET_NAME
MINER
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15308006
CURRENT_STATUS
02
SITE_LOCATION
1950 E MINER AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MINER\1950\PR0504240\INSTALL\1995 INSTALL .PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> OPTIONAL WATER HOSE REEL MOUNT TO STAND W/(4)-BOLTS & e— <br /> FOR WARMER CLIMATES USING MAX. BOLT SIZE FOR EACH w <br /> � <br /> REEL' / " OPTIONAL WATER HOSE <br /> REEL FOR WARMER CUMAIES a <br /> AIR HOSE REEL •�-`�; 4- <br /> C" O <br /> AIR HOSE REEL <br /> 1/2' FLEX HOSE <br /> s MOTOR OIL REEL I iF M <br /> HYDRAULIC HOSE j <br /> ' I AIR CHUCK M <br /> I , WOODFORD 10-WA <br /> MOTOR OUTLET CONTROL I 6'x 6' STEEL POSTS VARIABLE FLOW 0 �" <br /> WATER HYDRANT <br /> 5/3' D.D. HYDRAULIC STEEL TUBING M <br /> SHUT-OFF VALVES (TYP) I <br /> 1 4 VIEW B Lr) J <br /> :--OPTIONAL WATER LINE <br /> MOTOR OIL REELAIR HOSE REEL-TOP <br /> = <br /> PIPE SUPPORT (TYP.) <br /> 0 KIOSK i *, -_ WATER HOSE HANGER-BELOW Q <br /> I'I 5"x 6" STEEL POSTS L_ OPTIONAL WATER <br /> 10 n i- <br /> ') 'oI 6'x 6' STEEL POSTS �'i WATER NOSE HANGER Q HOSE REEL FOR m <br /> p4�OQ WATER HOSE HANGER 18'x 5' FUELAIOSK VIEW A WARMER CLIMATES 0 <br /> 6' STEEL PIPE SLEEVE ;II MTL. FORM ISLAND L1 z <br /> (MOTOR OIL) • <br /> Liles <br /> MWNIID 36' AF.f. I `o <br /> !i1 WATER NOZZLE N 2" HOSE RETRACTORPIPE o Q LLJ ry <br /> 1 0 a Q <br /> 1 <br /> I III <br /> PIPE SUPPORTS (TYP) � I WOODFORD 10-WA VARIABLE WOODFORD 10-WA <br /> FLOW WATER HYDRANT (ENCL VARIABLE FLEW 18"x 25' <br /> M j IN 2' WD.x 3' DEEP GRAVEL FILL) • WATER HYDRANT <br /> SHEAR SECTION BOLT W/(4) ALUM. GASOLINE <br /> BOLTS, MAX• SIZE OF HOLESS. SHUTOFF VALVE WITH DRAIN iv DISPENSER <br /> BOT. OF SHEAR SECTION , FOR OPTIONAL WATER SYSTEM <br /> FLOOR DRAIN <br /> G = P FLOOR IN <br /> 2' FRP (EXT.) AND/OR a �- <br /> 'TOTAL CONTAINMENT' W/ " - - 6' CONC. SLAB <br /> 5/B' HIGH PRESSURE <br /> HYDRAULIC HOSE OIL LINE FLEX 6CNNECTCR oY O ' PVC PIPE TO op FOP VIEW <br /> 4 <br /> HYDRAULIC UNE FROM OIL PUMP -^-- ------- -- -------- • DRAINAGE SYSTEM <br /> N <br /> 1/2- HIGF4 PRESSURE CU AIR UNE <br /> ; . <br /> 3/4- C.U. WATER LIN 4A. <br /> }'H . Oo <br /> BOTOF STAND O 2� WIDE x T DEEP GRAVEL FILL <br /> 'v I • ', o'O <br /> ' �4:� a <br /> Ld <br /> I <br /> VIEW A VIEW B p <br /> L <br /> MOTOR OIL , AIR & WATER REED. POST ASSEMBLY LJLJ <br /> NOT TO SCALE ` , O <br /> IL <br /> 0 <br /> OPW 104AOW-1212 W/ U <br /> MANHOLE COVER (OR EO.) <br /> ' 8" CONC. SLAB W/ � 0 <br /> ROUND CONIC. TOP DPW 634TTM-7087 6x6 6/6 W.W.M. Z <br /> e ,a MONITOR WELL CAP & #5s E.W. m M.H. Q <br /> W LOCK J <br /> BOLT TO COL. USING MAX. <br /> DOLT TO COL. USING MAX a 8" DIA.N 8'-0'� LONG - ' 3. _ - -- -+� — — — 11 L�j <br /> SIZE DOLTS PER BASE SIZE x r <br /> SIZE BOLTS PER BASE SIZE SCHEDULE 40 51EEL :•p . .,(� O:p <br /> DRILL HOLE IN COL . , <br /> FOR ROO ADJUSTMENT FILLED W/ CONCRETE .�,' II II <br /> STEEL COLUMN ' <br /> 3/4" GALV. STL. CONDUIT <br /> EXPANDABLE CONCRETE --� 1.,' I TO ISL. FOR FUTURE ELEC. <br /> �t MONITORING (OPTIONAL) <br /> in I :x <br /> BASE PLATE O r 4" PVC PIPE ' NOTE: WELLSCREEN MUST EXTEND AT LEAST <br /> IN. <br /> M3/8HANGER CLAMPS - 4' ROD 3/4' 10 1'' - SAES MAY VARY, 2 FT. ABOVE THE NORMAL ANNUAL <br /> (LENGTH TO SUIT WHEN ONLY I-CLAMP, BENTONITE SEALRA <br /> HIGH GROUND WATER TABLE AND <br /> HANGER MMP JOB.) TOP VIEW INSTALL IN CENTER 4 I EXTEND TO AT LEAST 2 FT. BELOW " <br /> SILICA SAND PACKED �, , THE BOTTOM OF THE TANK. IN i <br /> TOP MEW < � CASES WHERE THE WATER TABLE IS <br /> HANGERS W/ EXTENSION FIN. PAVEMT, OR CONC. II I II ENCOUNTERED, THE WFT. INTO <br /> T MUST <br /> EXTEND AT LEAST 3 FT. INTO THE <br /> 4 II II GROUNDWATER, <br /> THE WELL MUST COMPLY WITH ALL LOCAL <br /> - Vo nn Dpo. 000 00 Qo a od o�— COMP. FILL I I AND STATE CODES. SOME STATES REQUIRE <br /> A 25 FT. DEPTH FOR THE WELL. <br /> \\/ �� ° 4 4 /\\//\\// PIPE SCHEDULE DTTED (0.015C SLOT) I=_ GROUNDWATER TABLE <br /> HOLES FOR BOLTS <br /> o ° 4 4" NON-PERF, PVC <br /> m 4 (SOLID PIPE) - <br /> 14 <br /> ELEVATION OTiOM OF MONITOR WELL <br /> PVC CAP Lv <br /> HANGER W/ PLATE % FOOTING (SQUARE OR <br /> \) ROUND HOLE) z <br /> \\ \\/�\ 10BORING NOTE: MONITOR WELLS WILL BE INSTALLED O <br /> ��/j�//� -,�' ,�• ONLY WHEN REQUIRED BY LOCAL OR z <br /> STATE LAWS. CONSULT WITH PENSKE <br /> �— 12" 12" � PROJECT MANAGER. 5 <br /> PIPE HANGERS 2'-D" J <br /> NOT 10 SCALE OBSERVATION ( MONITOR ) WELL C <br /> PIPE BOLLARD NOT TO SCALE (USE ONLY WHEN LOCAL REGULATIONS REQUIRE) V) <br /> i" <br />
The URL can be used to link to this page
Your browser does not support the video tag.