'�w� tvis <br /> AIFIED PROGRAM CONSOLIDATED FOi sZ <br /> y UNDERGROUND STORAGE TANK p3 �s <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(One form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections 1,11,111,IV,and IX below) 430 <br /> 1.NEW PERMIT ❑ 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 4308 DATE EXISTING UST DISCOVERED: 4;Ob <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) _ _ Z ' o .3 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) ; <br /> SA r,1 oA Q u 1 <br /> BUSINESS SITE ADDRESS 103 CITY <br /> T 104 <br /> IL TANK DESCRIPTION <br /> TANK ID# 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> C wv "T A J/Y M LF Iy"T I:I.A STAND-ALONE TANK <br /> GTL fit) 5 oL V T2 d i v S <br /> [12.ONE INA COMPARTMENTED UNIT. <br /> Complete one page for each compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> JD L ejqcw <br /> III.T USE AND CONTENTS <br /> TANK USE la.MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING E] 1c.AVIATION FUELING 439 <br /> 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 4398 <br /> CONTENTS PETROLEUM: V la.REGULARUNLEADED ❑ Ic.MIDGRADE UNLEADED ❑ 1b.PREMIUM UNLEADED 440 <br /> 0-3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 4406 <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL JA 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL I1 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL j$3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify): 445a <br /> OVERFILL PREVENTION I.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT AM 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑I.SINGLE-WALLED ❑2.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE ❑ 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§2636(aX3)] 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 4646 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPING/TURBINECONTAINMENT SUMP TYPE ❑ I.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 4644 <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 464e1 <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL 4.FIBERGLASS 10.RIGID PLASTIC ❑ 90.NONE 99.OTHER(Specify) 464f <br /> 464fl <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL fig 4.FIBERGLASS 10.RIGID PLASTIC El 90.NONE ❑ 99.OTHER(Specify) 4648 <br /> 464&1 <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL ja 4.FIBERGLASS ❑ 10.RIGID PLASTIC 90.NONE 0 99.OTHER(Specify) 464h <br /> 464hl <br /> VENT PIPING TRANSITION SUMP TYPE 1.SINGLE WALL 2.DOUBLE WALL El 90.NONE 464'. <br /> RISER PRIMARY CONTAINMENT IX L STEEL 0 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4641 <br /> 464'1 <br /> RISER SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS 10.RIGID PLASTIC 0 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 464kl <br /> FILL COMPONENTS INSTALLED 25 1.SPILL BUCKET 3.STRIKER PLATE/BOTTOM PROTECTOR 4.CONTAINMENT SUMP 451a-c <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALT_ ❑ 3.NO DISPENSERS ❑ 90.NONE 469a <br /> CONSTRUCTION MATERIAL ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469b-c <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL.ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: 1 certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and in full compliance with legal re vire <br /> 470. <br /> APPLICANT SIGNATUR 'k5aEo_ DATE LJ r O ' 1 <br /> 471 APPLICANTTITLE y ar <br /> APPLICANT NAME(print) _ <br /> ' 'RsvnF Col�1TR�4cTOjR. <br /> UPCF UST-B-1/2 Rev.(12/2007) <br />