My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
INSTALL_2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2019 1:12:59 PM
Creation date
11/7/2018 8:18:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2015
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\M\MYRTLE\2849\PR0538822\INSTALL\2015 INSTALL SR0069410\GENERAL INSTALL PAPERWORK.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
238
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I. MONITORING: All monitoring equipment must be listed in the State Waster Resources Control Board <br /> Division of Clean Water Program Local Guidance Letter 113. <br /> Check Code <br /> Box Section <br /> All secondary containment units (e.g. tank annular spaces, secondary piping, sumps, <br /> 2632cR under-dispenser containment, etc.) monitored for leaks using approved electronic leak <br /> 2636(f) detections stems. <br /> All sensors must be located at the lowest possible point so that they may detect a leak <br /> at the earliest opportunity. <br /> Electronic monitoring sensors located at the following points: <br /> ° At the bottom of the interstitial space of each secondarily-contained tank, <br /> positioned as near as possible to the bottom of the tank. <br /> Manufacturer VEEDC-g gc,d�Model -r -..5 3 S-(:> <br /> ° In each collection sump, positioned as near as possible to the bottom of the <br /> collection sump. Additionally, in any sump acting as secondary containment for <br /> unused tank openings which connect to the primary space. <br /> 23 CCR Manufacturer VEEnE1:? go6wModel TLS 3 So <br /> Lil 2632 <br /> 2630(d) <br /> ° In dispenser pans which do not drain into secondary containment piping. <br /> (Note:A mechanical switch which triggers a shear valve may be substituted but <br /> this system will not qualify for the annual line tightness test exemption under 23 <br /> CCR 2636(g)). �j <br /> Manufacturer Model <br /> L Along secondarily-contained pipe runs which do not meet the 1/4 inch-per-foot <br /> slope requirement, positioned in the depressed or low-lying areas. <br /> Manufacturer Model <br /> 23 CCR Automatic line leak detectors installed to monitor underground pressurized piping. <br /> 2636(0 <br /> HSC ManufacturerVEEC)I=TZ 2derModel <br /> 25290.1 h <br /> 25290.2 <br /> Alarm panel provides both audible and visual alarms. It is located in a protected area <br /> and within sight and hearing distance of on-site personnel and hard-wired to a <br /> 23 CCR dedicated circuit. <br /> 2632(c)(2)(B) <br /> ManufactureryF_E•PE' gorr Model -T-LS :?S--D <br /> J. OTHER COMPONENT INFORMATION: <br /> COMPONENT MANUFACTURER MODEL COMPOSITION <br /> Cot-4'rHINMF- pWPTSLj-�wT3 Fr"- f=� <br /> SUMP SO L V 7-1 s <br /> UNDER-DISPENSER g A v & a0c),. 1=15"'S F }2 <br /> CONTAINMENT <br /> PENETRATIONS ST }TN c> 120 L{ 0--626-0 F K F"S <br /> Revised 07/24/13 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.