My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2015 APPROVED PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
INSTALL 2015 APPROVED PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2018 10:35:23 AM
Creation date
11/7/2018 8:24:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2015 APPROVED PLANS
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\M\MYRTLE\2849\PR0538822\INSTALL\2015 INSTALL SR0069410\APPROVED PLANS.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FILL SWIVEL ADAPTOR <br /> WITH DUST CAP <br /> <S>F <br /> MANHOLE SINGLE-PORT LEAK DETECTOR CONTAINMENT MANHOLE <br /> ELECTRIC JUNCTION MANHOLE SUBMERSIBLE SEE DETAIL "4" SOLUTIONS <br /> BOX-EXPLOSI N PROOF PUMP DWG. "FS9.03" <br /> s <br /> " COPPER ., MAG PROBE 12340 Santa Monica Blvd. Suite 133 <br /> „ SIPHON LINE MINI-HYDROSTATIC Los Angeles, CA 50025 <br /> TO LEAK BULKHEAD FITTING SENSOR 310/207-8548 <br /> MINI-HYDROSTATIC DETECTION PANEL ELECTRICAL <br /> BRINE SENSOR DOUBLE WALL SUMP vnC-�� TO VACUUM SENSOR MANIFOLD <br /> TO LEAK DETECTION BALL VALVE ( YP.) CONTAINMENT SOLUTION IN PUMP SUMP: }" HOSE INSIDE „_.. <br /> PANEL U.G. VACUUM SENSOR FLEX CONNECTOR 2" PRIMARY "SMITH" FIBERGLASS <br /> MANIFOLD PIPING: ' HOSE INSIDE (TYP.) LEVEL PROBE SCH. 40 PIPEI IV <br /> 3" SECONDARY "SMITH" FIBERGLASS p�yJFEssq � <br /> LEAK ENSOR 2" PRIMARY "SMITH" FIBERGLASS <br /> FLEX HECTOR <br /> 3' SECONDARY "SMITH" FIBERGLASS ro VACUUM SENSOR <br /> 2" IN 3" D.W. "SMITH" 3"D.W. " U.G. DIESEL VENT <br /> ° . SMITH" F.R.P. PIPE Z <br /> SINGLE WALL 3^ IN 4" D.W. "SMITH" F.R.P. SIPHON PIPE La <br /> 4" "SMITH" FIB RGLASS F.R.P. PIPE (To (FROM DT-1 TO DT-2) <br /> � No. M-32 51 <br /> SUMP PUMP SUMP PUMP DOUBLE WALL SUMP EXP. o06/30/2015FUEL/BRAKE LANES BLDG.) <br /> CONTAINMENT SOLUTION � <br /> 2" IN 3" D.W. "SMITH"4 SP1-1 SP1-2 <br /> F.R.P. PIPE TO FUEL ISLAND SUMP SENSOR SUMP SENSOR 4"X4"X3„ qp� cr-IArsI lF �s <br /> (DT-1 TANK ONLY) OF CAL <br /> BALL VALVE SIPHON LINE EXTRACTOR <br /> (TYP.) {t FS9.03 2 1� <br /> �J) BALL FLOAT <br /> SUCTION TUBE FLEX CONNECTOR VENT VALVE <br /> SIPHON LINE OPERATION. OVERFILL <br /> THE SIPHON LINE BETWEEN THE TWO DIESEL TANKS WILL MAINTAINED SIMILAR FUEL DROP TUBE <br /> VEDEER-ROOT LEVELS IN THE TANKS SO NO TANK IS EMPTIED DUE TO ONE ISLAND BEING USED MORE <br /> INVENTORY PROBE Peterson Hydraulics, Inc. <br /> 1653 W.El Segundo Blvd.,Los Angeles,CA 90249 <br /> Phone:(310)323-3155 Fax:(310)323-3606 <br /> Licenselt 631515 www.petersonhyd.com <br /> "Providing Service To The Vehicle Service Industry" <br /> II <br /> STRIKER PLATE, O <br /> � <br /> STRIKER PLATE, TYP. <br /> TYP. <br /> n <br /> NOTE: IF BOTH TYPES OF OVERFILL PREVENTION SYSTEMS (BALL FLOAT AND FILL TUBE <br /> VALVE) ARE INSTALLED, THE BALL FLOAT MAY INTERFERE WITH THE OPERATION T <br /> OF THE FILL TUBE VALVE IF THE BALL FLOAT IS INSTALLED LOWER THAN THE <br /> FILL TUBE VALVE. THEREFORE, THE BALL FLOAT SHOULD BE INSTALLED AT A 2 <br /> DIESEL TANKS DT1 & DT2 - PUMP SUMP DETAIL: HIGHER LEVEL THAN THE FILL TUBE VALVE SO THAT THE FILL TUBE VALVE IS <br /> SCALE: N.T.S. ACTIVATED PRIOR TO ANY FLOW RESTRICTION. <br /> DIESEL TANKS DT1 & DT2 - FILL SUMP DETAIL: <br /> SCALE: N.T.S, <br /> "VEEDER-ROOT' PRESSURIZED <br /> CHECK VALVE 2" BALL VA LINE LEAK DETECTOR (TYP.) <br /> 2 XP FE PETRO TURBINE T "VEEDER-RO T' <br /> (TYP. 2 PER SUMP) LEAK ETEC DO PA EL SUMP SENSOR INSTALLATION NOTES: <br /> DOUBLE WALL FRP SUMP <br /> "CONTAINMENT SOLUTION' <br /> "SMITH' x• IN 3" D.W. 1. THE SUMP SENSOR MUST BE POSITIONED AS CLOSE TO THE <br /> PIPE ENTRY JUNCTION BOX LEADER CABLE CONTAINMENT SUMP OUTER WALL AS POSSIBLE. <br /> 2• IN 3" D.W. "SMITH' EXPLOSION PROOF LL <br /> F.R.P. PIPE TO FUEL ISLAND YRP 2"X12" M SWIVEL <br /> FLEX CONNECTOR 2. THE SUMP SENSOR MUST BE POSITIONED IN THE LOWEST �- <br /> (DT-1 TANK ONLY) " j�' r ..�±'fix__ Iii RIGID ELECTRIC SUMP SENSOR PART OF THE SUMP. <br /> !. 2" SCK 40, BLACK <br /> IRON ELBOW CONDUIT <br /> z^ "SMITH' "BELL X MALE' SLEEVE CEMENTED TO 3. THE SUMP SENSOR MUST BE MOUNTED IN A TRUE VERTICAL <br /> THREADED ADAPTER z"xz^x3" scH. 40. SUMP WALL (SEE NOTE 6) POSITION TO ENSURE PROPER OPERATION OF THE FLOAT <br /> BLACK IRON TEE SWITCH CONTAINED INSIDE. <br /> 3" SCK 40, BLACK <br /> IRON ELBOW "BRAVO" D.W. ELECTRICAL 4. WHEN INSTALLED, THE SUMP SENSOR MUST REST ON THE <br /> 3" IN 4" D.W. "SMITH' 4" SCK 40, RISER BULKHEAD FITTING BOTTOM OF THE SUMP. <br /> F.R.P. PIPE (To DOUBLE WALL SUMP <br /> FUEL/BRAKE LANES BLDG.) CONTAINMENT SOLUTION 5. THE WIRES BETWEEN THE "VEDEER-ROOT' MONITOR AND <br /> TOL OF <br /> TAN EACH SUMP SENSOR LOCATION MUST BE OF A TYPE DESIGNED <br /> 3" SCH. 40, BLACK FOR USE IN THE PRESENCE OF DIESEL, AND IN ACCORDANCE KEY PLAN <br /> "SMITH" 3" IN 4" D.W. IRON PIPE WITH MANUFACTURER'S RECOMMENDED INSTALLATION <br /> PIPE ENTRY <br /> 3"X3"X2" SCH. 40, BLACK PROCEDURES. WIRES BETWEEN TURBINES AND VARIABLE <br /> *ALVE <br /> " D.W, ELECTRICAL SMITH' BEL X MALE' <br /> IRON TEE (DT-1 TANK ONLY) FREQUENCY CONTROLLER SHALL BE INSTALLED PER "FE <br /> PETRO'S" INSTALLATION AND OWNERS MANUAL. THE CONDUIT <br /> ELECTRIAD FITTING <br /> MUST BE PROPERLY SEALED IN ACCORDANCE WITH THE <br /> NATIONAL ELECTRICAL CODE (N.EC. 70) AND THE AUTOMOTIVE <br /> AND MARINE SERVICE STATION CODE (N.F.P.A. 30) SINCE THEY <br /> COUPLER PASS FROM CLASS I, DIVISION 1 OR DIVISION II AREA INTO A FIRE DEPARTMENT <br /> NON-HAZARDOUS AREA. <br /> DOUBLE-WALLED FIBERGLA3" SCH 40, BLACK IRON SUBMITTAL <br /> PRODUCT PIPIN6. FOR PUMP SUMP SENSOR INSTALLATIONS, SELECT A <br /> BLACK I SCH 40, <br /> �,v,���, BLACK IRON TEE POSITION FOR THE MOUNTING SLEEVE AT THE LOWEST POINT <br /> (DOUBLE WALL FRP SUMP IN THE SUMP, WHICH IS CAPABLE OF DETECTING AN REVISION BY DATE <br /> �(•CO,nTAINM6NT SOLUTIO UNAUTHORIZED RELEASE FROM ANY PORTION OF THE AS PER ENVIRONMENTAL HEALTH J.W. 042914 <br /> BUL2"X12' M SWIVEL UNDERGROUND STORAGE TANK SYSTEM AT THE EARLIESTm DEPARTMENT CORRECTIONS <br /> LEAK DETECTION FLEX CONNECTOR POSSIBLE OPPORTUNITY. ® AS PE0. ENVIRONMENTAL HEALTH R.V.F. 082014 <br /> 3"(2") SMITH ' BELL X MALE" DEPARTMENT CORRECTIONS <br /> DOUBTHREADED ADAPTER 3' SCH. 40, <br /> CONTAINMENT SOLUTION BLACK IRON PIPE 2 HP FE PETRO TURBINE 7. EPDXY SEALANT BAGS ARE FOR TWO WIRE NUT <br /> (TYP. 2 PER SUMP) CONNECTIONS ONLY. IMPROPER SEALING OF THE CONNECTIONS <br /> 3"X3"X2" SCH. 40, <br /> WILL RESULT IN AN INACCURATE SENSOR READING AND <br /> BLACK IRON TEE <br /> (DT-1 TANK ONLY) q POSSIBLE FALSE ALARM CONDITIONS. <br /> "SMITH' 3" IN 4" D.W. - FS9.03 8. INSTALLER SHALL FOLLOW SENSOR MANUFACTURER'S <br /> PIPE ENTRY - INSTALLATION GUIDE SHIPPED WITH SENSOR UNITS FOR SAN JOAQUIN RTD <br /> (DT-1 TANK ONLY) !-- .-.- - -��-�-- COMPLETE INSTALLATION INSTRUCTIONS AND PROCEDURES. <br /> 2" S H "BELL X MALE" <br /> THRE DED ADAPTER <br /> SAN JOAQUIN RTD REGIONAL <br /> LEAK DETECTION <br /> TRANSIT CENTER <br /> ULKHEAD DETAIL 5 UMP SENSOR DETAIL <br /> (3 SCALE: N.T.S. 2" IN 3" D.W. "SMITH' SCALE: NT.S. <br /> F.R.P. PIPE TO FUEL ISLAND <br /> Dv� (DT-1 TANK ONLY) <br /> Q 3 SMITH "BELL X MALE' <br /> THREADED ADAPTER "SMITH' 2" IN 3" D.W. <br /> PIPE ENTRY DIESEL FUEL TANKS <br /> (DT-1 TANK ONLY) <br /> DT- 1 & DT-2 DETAIL <br /> URBINE LEAK DETECTOR DETAIL. 83023.00 <br /> 4' SCALE: NTS. <br /> AS NOTED <br /> a 17 APRIL, 2014 <br /> a <br /> NORTH FS9 . ® 3 <br /> M <br />
The URL can be used to link to this page
Your browser does not support the video tag.