My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINDSAY
>
1533
>
2300 - Underground Storage Tank Program
>
PR0231158
>
REMOVAL_2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2022 2:44:48 PM
Creation date
11/8/2018 9:35:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2014
RECORD_ID
PR0231158
PE
2361
FACILITY_ID
FA0003749
FACILITY_NAME
SJ REGIONAL TRANSIT
STREET_NUMBER
1533
Direction
E
STREET_NAME
LINDSAY
STREET_TYPE
ST
City
STOCKTON
Zip
952054498
APN
15302004
CURRENT_STATUS
02
SITE_LOCATION
1533 E LINDSAY ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\L\LINDSAY\1533\PR0231158\REMOVAL 2014.PDF
QuestysFileName
REMOVAL 2014
QuestysRecordDate
3/25/2016 4:38:22 PM
QuestysRecordID
3031124
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
331
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br />UST WORKSHEET FOR SITE CLOSURE EVALUATION <br />I. FACILITYITANK INFORMATION DATE: April 4, 2014 <br />SITE/FACILITY NAME: j SJ RTD STATUS CODE: 1 50 <br />ADDRESS: 1533 Lindsay CITY: I Stockton <br />FA#: FA0003749 PR#: PR0531158 TANK# 39-0115819,39-0115820 (split <br />TANK SIZE: 1,000 11,000 gallon FUEL TYPE: Regular /Transmission Oil s lit tank (RTD & samples refer as T5 & T6) <br />II. GENERAL SITE HISTORY <br />Is Permit Current? Yes Documented Soil/GW Contamination?'" No <br />Number of Tanks at Facility 8 Age of Tanks (if available) 22 year Type of Tank :Fiberglass <br />III. TANK HISTORY <br />Was Tank Tested? ❑ Yes x No <br />Failed Testing? ❑ Yes x No <br />If Yes, Provide Dates: <br />Was Tank System Repaired? ❑ Yes ❑ No <br />If Yes, Describe Repair: <br />Was Repair Done Under Permit? E3 Yes E3 No <br />Were Soil Samples Analyzed? x Yes E3 No <br />T5: BTEX, TPH-G, 5 Oxy, -kTPDCA/EDB <br />T6: BTEX, TPH-d, TPH-k,, TPH-mo <br />Type of Failure/Discharge: ❑ Catastrophic ❑ Long-term Leak ❑ Overfill ❑ Unknown ❑ Other <br />R��:7dd,f�V/d �:Ir.9 f�1:1//S:&L7771rd <br />Soil Samples Received? ❑ Yes ❑ No <br />Seasonal High Depth to GW 33 ft bgs <br />Year/ Reference <br />1983 <br />Onsite and/or Nearby Well(s)? Yes <br />❑ Irrigation: # Distance to Tank ft <br />C <br />Score 10 <br />C <br />Score 9 <br />C <br />❑ Domestic: # Distance to Tank ft <br />0 <br />points if <br />0 <br />points if <br />0 <br />Score 5 points if <br />❑ Public: # Distance to Tank ft <br />R <br />E <br />condition is <br />met <br />R <br />E <br />condition is <br />met <br />R <br />E <br />condition is met <br />V. SITE FEATURE— LEACHING POTENTIAL ANALYSIS <br />Minimum Depth to Groundwater from Soil Sample (feet) <br />>100 <br />51-100 <br />5 <br />25-501 <br />Fractures in Subsurface (applies to foothill or mountain areas) <br />10 <br />None <br />Unknown <br />Present <br />Average Annual Precipitation (14 inches for SJC area) <br />-------- <br /><10 <br />9 <br />10-25 <br />-------- <br />26-402 <br />Man -Made Conduits which Increase Vertical Migration <br />None <br />9 <br />Unknown <br />Present <br />.e. septic sstems, water wells, ponds): transite waterline, gas line <br />Unique Site Features: Recharge Area, Coarse Soil (coarse sands, <br />10 <br />None <br />At Least One <br />More Than One <br />gravels), nearby wells <br />Column Totals Total Points <br />20 <br />+ <br />18 <br />+ <br />5 <br />= 43 <br />Sample Results for BTEX: <br />Range of Total Points <br />49 Points or More <br />41 — 48 Points <br />40 Points or Less <br />NO @ 0.005 mg/kg) <br />Maximum Allowable BTEX <br />B <br />T <br />I E <br />X <br />B <br />T <br />E <br />1 X <br />N/A3 <br />Levels m <br />1.0 <br />50 <br />50 <br />50 <br />0.3 <br />0.3 <br />1.0 <br />1.0 <br />Sample Results for TPH: <br />Maximum <br />I Gasoline <br />1,000 <br />100 <br />10 <br />NO @ 1 mg/kg for gas <br />Allowable TPH <br />ND @ 5mg/kg for diesel <br />Levels m <br />Diesel <br />10,000 <br />1,000 <br />100 <br />Footnotes: ***If documented soil and/or groundwater contamination is present, do not complete leaching potential analysis (i.e. site is already on the contamination list). <br />1 If depth is>5 feet and < 25 feet, score 0 points. If depth is <=5 feet, do not use table. 2 If precipitation is> 40 inches, score 0 points. <br />3 Levels for BTEX are not applicable at a concentration of 10 ppm for TPH-Gasoline or 100 ppm for TPH-Diesel, <br />VI. STAFF RECOMMENDATION/ REFERRALI REVIEW <br />1. Are BTEX or TPH Concentrations > Allowable Levels? No <br />2. If No, Is Site Closure Recommended? Yes <br />Completed By: Jeffrey Wong <br />Date Referred to Site Mitigation Unit for Final Actiont p <br />Reviewed By: <br />Concur with Staff Recommendatio s ❑ No <br />Date Closure Letter Maile <br />tAII Cases are Referred to Site Mitigation for Final Action <br />EH 23-0080 (Rev 11/14/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.