Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> se By All Jurisdictions Within the State of Califo <br /> Authority Cited:Chapter 6.7, and Safety Code;Chapter 16,Division 3 Title 23, alifomia Code of Regulations <br /> This forth must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The ownedoperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: USA#65 City: LODI CA Zip:95242 <br /> Site Address: 2500 W.LODI AVE. Contact Phone No:333-9834 <br /> @ LOWER SACRAMENTO RD. Date of Testing/SerAce: 11/06/2003 <br /> Facility Contact Person: MGR-SHARON <br /> Make/Model of Monitoring System: VEEDER ROOT TLS Work Order Number. 2228896 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: SUPER Tank ID: DIESEL <br /> X In-Tank Gauging Probe. Model: MAG 1 X In-Tank Gauging Probe. Model: MAG 1 <br /> X Annular Space or Vault Sensor. Model: 794390-420 Annular Space or Vault Sensor. Model: 794390420 <br /> X Piping Sumprrmnch Sensor(s). Model: 794360-206 Piping Sumprrrench Sensor(s). Model: 794380-208 <br /> X Fill Sump Sensor(s). Model: 794380-208 Fill Sump Sensor(s). Model: 794380-208 <br /> Mechanical Line Leak Detector. Model: FX1 V Mechanical Line Leak Detector. Model: FX1DV <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> TankID: Tank ID: <br /> R1 In-Tank Gauging Probe. Model: MAG 1 In-Tank Gauging Probe. Model: MAG 1 <br /> X Annular Space or Vault Sensor. Model: 794390-420 Annular Space or Vault Sensor. Model: 794390-420 <br /> X Piping Sumprfrench Sensor(s). Model: 794380-208 Piping Sumprrrench Sensor(s). Model: 794360-208 <br /> X Fill Sump Sensor(s). Model: 794380-208 Fill Sump Sensor(s). Model: 794380-208 <br /> X Mechanical Line Leak Detector. Model: FX1 V Mechanical Line Leak Detector. Model: FX1 V <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1-2 Dispenser lID: 4-5 <br /> X❑Dispenser Containment Sensor(s) Model:794380-208 X Dispenser Containment Sensor(s) Model:794360-208 <br /> Q Shear Valve(s). X Shear Valve(s) <br /> Dispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 7-8 Dispenser ID: 6 <br /> Q Dispenser Containment Sensor(s) Model:794380-208 Dispenser Containment Sensor(s). Model:794360-208 <br /> XD Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 3 Dispenser ID: <br /> Pq Dispenser Containment Sensors) Model:794360-208 Dispenser Containment Sensor(s). Model: <br /> X� Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up report; ❑ Alarm history report l <br /> PRINTED NAME ANEIL CHAND SIGNATURE: )-1lJ <br /> COMPANY: Tanknology PHONE NO: (800)800-4633 <br /> page 1 of 3 Based on CA form dated 03101 <br />