My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
2500
>
2300 - Underground Storage Tank Program
>
PR0231356
>
COMPLIANCE INFO 1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2024 2:28:08 PM
Creation date
11/8/2018 9:36:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0231356
PE
2361
FACILITY_ID
FA0003815
FACILITY_NAME
TESORO (MOBIL) 68154
STREET_NUMBER
2500
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
02740006
CURRENT_STATUS
01
SITE_LOCATION
2500 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\L\LODI\2500\PR0231356\COMPLIANCE INFO 1998-2006.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUR TANK INFORMATION AN ST RESULTS <br /> .,; i 7animo%gy <br /> 8900 SHOAL CREEK, BUILDING 200 WORK ORDER NUMBER: 2218951 <br /> TEST DATE: 10/10/01 AUSTIN,TEXAS 76757(512)451-6334 <br /> CLIENT: USA PETROLEUM SITE: USA #65 <br /> Tank ID: 6K 4 Tank manifolded: No Bottom to top fill in inches: <br /> Product: DIESEL Vent manifolded: No Bottom to grade in inches: <br /> Capacity in gallons: 6,016 Vapor recovery manifolded: No Fill pipe length in inches: <br /> Diameter in inches: 96.00 Overfill protection:yES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 195 Overspill protection:yEs Stage I vapor recovery: NONE <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: NONE <br /> CP installed on: <br /> COMMENTS <br /> TANK <br /> el G ° \ est met od: <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: gvn JACKET <br /> Fluid volume in gallons: Model: ru.D <br /> Tank water level in inches: SIN: 8129 <br /> Test time: Open time in sec: 2.90 <br /> Number ofthermisters: NOT <br /> Holding psi: NOT <br /> Specific gravity: TESTED Resiliency cc: TESTED <br /> Watertable depth in inches: Test leak rate mum: 189.0 <br /> Determined by(method): Metering psi: 10 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> TESTtILLLA I ,Ittr ' Oi <br /> Testtime: Material: ENVIRON <br /> Ullage volume: Diameter(in): 1.5 <br /> Ullage pressure: Length (ft): 80.0 <br /> Results: Test psi: <br /> Bleedback cc: <br /> DATA FOR UTS4T ONLY: Test time (min): <br /> Test 1:Start time: <br /> Time Of test 1: Finish psi: NOT NOT NOT NOT <br /> Temperature: NOT change Cc: <br /> Testst 2:Start time: TESTED TESTED TESTED TESTED <br /> Flow rate(cfh): TESTED Finish psi: <br /> Time of test 2: Vol change cc: <br /> Test 3:Start time: <br /> Temperature: Finish psi: <br /> Flow rate (cfh): Vol change cc: <br /> Time of test 3: Final gph: <br /> Temperature: Result: <br /> Flow rate (cfh): Pump type: PRESSURE <br /> COMMENTS - Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational. UNKNOWN <br /> Printed 10/16/2001 08:13 CCHAPA <br />