My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
2500
>
2300 - Underground Storage Tank Program
>
PR0231356
>
COMPLIANCE INFO 1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2024 2:28:08 PM
Creation date
11/8/2018 9:36:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0231356
PE
2361
FACILITY_ID
FA0003815
FACILITY_NAME
TESORO (MOBIL) 68154
STREET_NUMBER
2500
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
02740006
CURRENT_STATUS
01
SITE_LOCATION
2500 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\L\LODI\2500\PR0231356\COMPLIANCE INFO 1998-2006.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITNG SYSTEM CERTIFITION <br /> se By All Jurisdictions Within the State of Califomi <br /> Authority Cited:Chapter 6.7,He h and Safety Code;Chapter 16,Division 3 Title 23, CMYornia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: USA#65 (N-903) City: LODI CA Zip:95242 <br /> Site Address: 2500 W.LODI AVE. Contact Phone No: 366-0703 <br /> @ LOWER SACRAMENTO RD. Date of Testing/Service: 07/05/2006 <br /> Facility Contact Person: MGR-BOBBIE <br /> Make/Model of Monitoring System:VRTLS350 Work Order Number: 2243688 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 87 Tank ID: 89 <br /> 71 In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: LS3 Annular Space or Vault Sensor. Model: LS3 <br /> _X1Piping SumprTrench Sensor(s). Model: 208 Piping Sumprrmnch Sensor(s). Model: 208 <br /> X Fill Sump Sensor(s). Model: 208 208 <br /> Fill Sump Sensor(s). Model: <br /> 71 Mechanical Line Leak Detector. Model: FXIVFX1V <br /> Mechanical line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank OverfilUHigh-Level Sensor. Model: MAG X Tank Overfill/High-Level Sensor. Model: MAG <br /> Other(specify equipment type and model in Section E on page 2). D Other(specify equipment type and model in Section E on page 2). <br /> TanklD: 91 Tank ID: <br /> X1 In-Tank Gauging Probe. Model: MAG 71 In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: LS3 Annular Space or Vault Sensor. Model: LS3 <br /> X1 Piping Sump/Trench Sensors) Model: 208 Piping Sump/Trench Sensor(4 Model: 208 <br /> X Fill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Model: 208 <br /> X Mechanical Line Leak Detector. Model: FX1 V Mechanical Line Leak Detector. Model: FX1 DV <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> X Tank Overfill/High-Level Sensor. Model: MAG X Tank Dvefill/High-Level Sensor. Model: MAG <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3 <br /> ❑Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s) Model: <br /> X❑Shear Valve(s). X Shear Valves) <br /> ❑X Dispenser Containment Float(s)and Chain(s). X Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 4/5 Dispenser 10: 6 <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> X❑ Shear Valve(s). il Shear Valve(s). <br /> FXJ Dispenser Containment Float(s)and Chain(s). X1 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 7/8 Dispenser ID: 9 <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> ❑X Shear Valve(s). Shear Valve(s). <br /> ❑X Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s) <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordancewith the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ❑X System set-upX❑Alarm history report <br /> Technician Name(print): RAYMOND SIMMS Signature: <br /> Certification No.: 006-05-0282 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-0633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 07/05/2006 <br /> Page 1 of 3 Based on CA form dated 03/01 <br /> Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.