Laserfiche WebLink
MONITNG SYSTEM CERTIFITION <br /> se By All Jurisdictions Within the State of Califomi <br /> Authority Cited:Chapter 6.7,He h and Safety Code;Chapter 16, Division 3 Title 23, C377fornia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control Panel by the technician who perforins the work. A copy of this forth must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this forth to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: USA#65 City: LODI CA Zip:95242 <br /> Site Address: 2500 W.LODI AVE. Contact Phone No: 366-0703 <br /> LOWER SACRAMENTO RD. Date of Testing/Service: 10/04/2005 <br /> Facility Contact Person: MGR-BOBBIE <br /> Make/Model of Monitoring System:TLS-350 Work Order Number. 2238773 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1-87 Tank ID: 2-89 <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: LS3 Annular Space or Vault Sensor. Model: LS3 <br /> 71 Piping Sump/Trench Sensor(s). Model: 208 Piping Sumpfrrench Sensor(s). Model: 208 <br /> 71 <br /> Fill Sump Sensorts). Model: 208 Fill Sump Sensor(s). Model: 206 <br /> -39 Mechanical Line Leak Detector. Model: FX1 VFX1 V <br /> Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank OvefilVHigh-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: Tank ID:—L-QIL— <br /> R1In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: LS3 Annular Space or Vault Sensor. Model: LS3 <br /> X Piping Sump/rrench Sensogs). Model: 208 Piping Sumpfrrench Sensor(s). Model: 206 <br /> X1 Fill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Model: 206 <br /> X Mechanical Line Leak Detector. Model: FX1V Mechanical Line Leak Detector. Model: FX1 DV <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank OverfilUHigh-Level Sensor. Model: Tank overfilVHigh-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). D Other(specify equipment type and model in Section E on page 2). <br /> Dispenser 1/2 Dispenser ID: 3 <br /> MDispenser Containment Sensors) Model:208 :Xj Dispenser Containment Sensor(s) Model:208 <br /> X❑Shear Valve(s). X Shear Valve(s) <br /> ❑Dispenser Containment Floats)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 4/5 Dispenser ID: 6 <br /> FX-1 Dispenser Containment Sensor(s) Model:206 Dispenser Containment Sensoria). Model:208 <br /> X❑ Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 7/8 Dispenser ID: 9 <br /> MDispenser Containment Sensor(s) Model:206 X Dispenser Containment Sensor(s). Model:208 <br /> FX Shear Valve(s). X Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> `If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ❑System set-up X❑Ala"history report <br /> Technician Name(print): DOUGLAS HARTY Signature: <br /> Certification No.: License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 10/04/2005 <br /> Page 1 of 3 Based on CA form dated 03/01 <br /> Monitoring System Certification <br />