My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOWELL
>
1975
>
2300 - Underground Storage Tank Program
>
PR0232521
>
COMPLIANCE INFO 2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 2:26:36 PM
Creation date
11/8/2018 9:38:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0232521
PE
2361
FACILITY_ID
FA0004044
FACILITY_NAME
TRACY USD - SERVICE CENTER
STREET_NUMBER
1975
Direction
W
STREET_NAME
LOWELL
STREET_TYPE
AVE
City
TRACY
Zip
95376
APN
23213008
CURRENT_STATUS
01
SITE_LOCATION
1975 W LOWELL AVE
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\L\LOWELL\1975\PR0232521\COMPLIANCE INFO 2004 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2007
QuestysRecordDate
11/29/2017 7:25:21 PM
QuestysRecordID
3737183
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
170
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LG 113 Vendor/Template Page t of L <br /> * � cap ► � �I � � wa - �� �� � <br /> Issue Date:August 23,1999 <br /> Revision Date: March 11,2004 <br /> Vaporless Manufacturing <br /> Vaporless 98LD-2000, 99LD-2000, 99LD-2200, LD-2200 Scout <br /> (for Rigid and Flexible Pipelines) <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification Leak rate of 3.0 gph with PD = 100% and PFA = 0%. <br /> Leak 2.5 gph. <br /> Threshold A pipeline system should not be declared tight if the test result indicates a loss that <br /> equals or exceeds this threshold. <br /> Applicability Gasoline, diesel, aviation fuel. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification System tests pressurized flexible, fiberglass, and steel pipelines. <br /> Tests are conducted at operating pressure. <br /> Pipeline Maximum of 172 gallons for rigid pipelines. <br /> Capacity Maximum of 39.5 gallons for flexible pipelines. <br /> Waiting Time None between dispensing and testing. <br /> None between delivery and testing. <br /> Test Period Response time is less than 1 minute without a leak and 1 to 8 minutes with a leak. <br /> System Permanent installation on pipeline. <br /> Features Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Restricted flow to dispenser if leak is declared. <br /> Calibration Equipment must be checked annually for capability of detecting a line leak of <br /> 3.0 gph and, if necessary, calibrated in accordance with manufacturer's <br /> instructions. <br /> Comments Functionality and operability of the 99 LD-2000 and 99 LD-2200 are unchanged by <br /> installation of the Leak Detection Sensor (piston switch) that supports the VMI ISM-4080 <br /> and ISM-4081 Integrated Shutdown Module. <br /> Vaporless Manufacturing Evaluator: Ken Wilcox Associates <br /> 8700 East Long Mesa Drive Tel: (816) 443-2494 <br /> Prescott Valley, AZ 86314 Dates of Evaluation: 05/20/98, 11/10/98 <br /> http://www.waterboards.ca.gov/ust/leak_prevention/lgl13/Vendor Files/vaporless_manu... 11/10/2005 <br />
The URL can be used to link to this page
Your browser does not support the video tag.