INSTALL_1992
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2650
>
2300 - Underground Storage Tank Program
>
PR0232573
>
INSTALL_1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 11:53:13 AM
Creation date
11/8/2018 9:39:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1992
RECORD_ID
PR0232573
PE
2361
FACILITY_ID
FA0003941
FACILITY_NAME
ORCHARD SUPPLY HARDWARE #1570
STREET_NUMBER
2650
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21307061
CURRENT_STATUS
02
SITE_LOCATION
2650 MACARTHUR DR STE A
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MACARTHUR\2650\PR0232573\INSTALL 1992.PDF
QuestysFileName
INSTALL 1992
QuestysRecordDate
8/2/2017 4:00:35 PM
QuestysRecordID
3544491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VSA Vapor Sensor Adaptor <br /> Adds vapor well monitoring to TLS-2501 Eight-Tank <br /> Systems for complete UST site management <br /> Wnen the VSA detects hydrocarbon vapor A Sensor Status Report from the TLS-250i <br /> k. or water or identifies an open or shorted sensor in shows the anent alarm condition of each sensor <br /> Y the system,an alarm report showing the type of channel in the VSA system. <br /> m alarm condition and location is generated by the <br /> TLS-2501. <br /> �.- . <br /> sh' VAPOR SEN90R STATUS <br /> t. - 1 NORMAL <br /> -- <br /> - SENSOR ALARM -- 2 NORMAL <br /> ■ _' CHANNEL 1 3 NORMAL <br /> ■ VAPOR SENSOR - VAPOR 4 NORMAL <br /> 5 NORMAL <br /> ' 'E <br /> OCT 1, 1989 6 NORMAL <br /> ® 9:24 AM 7 NORMAL <br /> 8. NORMAL <br /> ■ i 9 NORMAL <br /> 10 NORMAL <br /> I --- SENSOR ALARM --- <br /> CHANNEL 2 <br /> VAPOR SENSOR - WATER cc'' <br /> ® OCT 3, 3989 p rammablev pi <br /> i 11:�7 nog vapor alarm thresholds can f <br /> ■ be set for each channel in a VSA system to"tune <br /> out*acceptable background vapors. M{ <br /> Veeder-Root's new Vapor Sensor Adaptor side-mounted to the TLS-250i or mounted •---^----^^-'=�' ='" =-• Ei <br /> adds vapor well monitoring capability to the separately. <br /> TLS-2501 Eight-Tank System.Together,they Only two wires are needed to connect the <br /> provide the most complete,Integrated UST VSA to an existing channel in the TLS-2501 Con- VAPOR SETUP r <br /> site monitoring system available. sole where its input information is fully Integrated --- SENSOR ALARM --- VAPOR LIMIT VALUES j 2 <br /> with the TLS-250i reporting and alarm capabilities. CHANNEL 5 <br /> - When hydrocarbon vapors or waterers- Combined,the TLS-2501 and VSA provide VAPOR SENSOR - OPEN r CHANNEL 1: 10000 i <br /> - detected by a sensor,an alarm message den- complete,single-system UST montloring. I CHANNEL 2: 10000 1 <br /> tifyirg the type of alar and sensor number is OCT 7, 1989 CHANNEL 3: 10000 " <br /> = printed out by the TLS-2501.In addition,VSA VAPOR WELL MONITORING CAPABILITIES 7:35 AN !. CHANNEL s: 10000 <br /> alar outputs can be tied to TLS-2501 alar a Detects hydrocarbon vapor and water h CHANNEL 5: 10000 <br /> relaysto bigger on-site or remote alarms and can ;,,� "-r-^--�•-xr;,;rszs:. 1 CHANNEL 6: 30000 r. <br /> 99 . Atl Adjustable vapor + CHANNEL 1: 10000 <br /> � 1 por alarm thresholds to tune 5' <br /> be Interrogated via the TLS-2501 communications out acceptable background vapors la <br /> CHANNEL 8: 10000 <br /> interface. tt CHANNEL 9: 10000 1 <br /> ttit� The VSA will also generate alar messages ALARM CAPABILITIES i CHANNEL 10: 10000 <br /> to identify an open or shorted sensor in the - Uses TLS-2501 alar and reporting --- SENSOR ALARM --- <br /> system. <br /> � Sysl¢m. capabilities CHANNEL 10 _ <br /> Arammable vapor threshold a Warne of <br /> Pro9 Po pen armshortsd sensor VAPOR SENSOR - SNORT <br /> allows acceptable levels of existing vapors to be <br /> "tuned oul"when the VSA system is instated. SYSTEM CAPABILITIES ` OCT 12 1989 <br /> VSA vapor sensors are easily Installed in a Monitors up to 10 channels \ �- 4:45 PM <br /> standard 3"or 4'We45 and connect to the wnsole . Mounts on TLS-2501 console or separately , <br /> using only three wires.The VSA console can be - .�. s.• ^>;:==-: 7 <br />