Laserfiche WebLink
r..,_. <br /> Hydrostatic *k Normal Conditions <br /> Monitoring—For The reservoir liquid level will <br /> Concrete Optional Reservoir be stable if both the inner and <br /> Maximum Performance Liquid Level Sensor <br /> Traffic outer tank are tight. <br /> In Double-Wall Tank Pad Stable Reservoir <br /> Leak Detection . . .And Liquid Level <br /> Precision Tank Testing The optional reservoir sensor <br /> will activate an alarm if the <br /> "" ... Stored reservoir drains or overfills. <br /> Product <br /> `Double-Wall <br /> Underground Tank <br /> Inner Wail Breach <br /> Monitor fluid drains into the <br /> primary tank causing the <br /> Reservoir reservoir to drain. No <br /> f C sins petroleum product escapes <br /> Background from the primary tank to <br /> OIC TANKS recommends the pollute the site. <br /> Hydrostatic Tank Monitor for <br /> double-wall tank monitoring ' r <br /> because of its superior leak neer <br /> detection capability. By filling Wall <br /> the cavity between the inner Breach <br /> and outer tank walls with a <br /> liquid, hydrostatic pressure is <br /> continuously applied to both <br /> the primary and secondary Outer Wall Breach <br /> tank. This pressure is capable If the groundwater is below <br /> of detecting tank leaks in either the tank top, the monitor fluid <br /> the primary or secondary drains into the ground causing <br /> tank walls for all installed Groundwater the reservoir to drain. <br /> circumstances. Level <br /> The Hydrostatic Tank Monitor i <br /> can also serve the dual func- <br /> tion of a precision tank test. low ± <br /> Because the hydrostatic pres- st <u Outer Tank <br /> sure is continuous, this tank Breach <br /> testing method is less prone <br /> to potential false readings <br /> caused by minute changes in <br /> product temperature, tank If the groundwater is over the <br /> deflection under loads, or tank top, the reservoir will <br /> human error. overfill with groundwater and <br /> ' �Grrouulndwater activate the high level alarm <br /> The Hydrostatic Tank Monitor <br /> has been independently tested Rese veservoolr ;; on the reservoir sensor. <br /> and statistically validated to <br /> meet the National Fire Protec- <br /> tion Association's criteria as a <br /> precision tank test.This device <br /> is capable of detecting leaks <br /> k �.; <br /> as small as 0.05 gallons per : Outer Tank <br /> hour with a 95% probability of 'Breach <br /> detection and a 5% probability <br /> of a false alarm. [[[ <br /> All of the Fiberglas double- ■ <br /> wall tanks in this catalog <br /> include the "built-in" <br /> hydrostatic tank monitor as a <br /> standard feature. <br />