Laserfiche WebLink
Optional Accessories and piping. Do not use more thereby completing the elec- <br /> For Hydrostatic Tank than 75% glycol. trical sensing circuit (normally <br /> Monitoring closed). If the reservoir liquid <br /> level drains and exposes the <br /> Freeze Glycol Mixture sensor probes, an alarm will <br /> Protection (with water) sound at the electronic <br /> 20°F 200/, control panel. <br /> 0°F 30% <br /> –20°F 40% Reservoir Sensor <br /> –40°F 50% Model RS 10A Shown <br /> Water Paste Detection <br /> To detect water in the tank <br /> bottom, water detection paste CRISER <br /> STABLE <br /> is available from petroleum CABLE <br /> equipment distributors. How- I CONDO r <br /> ever, some water detection <br /> paste cannot detect antifreeze HIGH LIauIDPIPE CAPmixtures. If antifreeze mix- LEVELIIOLEStures are used for the cavity SWITCHRISERPIPE <br /> Antifreeze Mixtures monitoring fluid, the following FITTING <br /> O/C TANKS recommends product is capable of detecting 1I <br /> and supplies the Hydrostatic water or antifreeze (brine or INTERNALLY <br /> THREADED <br /> Tank Monitor for use with up to 50% glycol) solution in <br /> Fiberglas® double-wall tanks the tank water bottoms: PERFORATED <br /> (Models DWT-2P and DWT- WATER FINDER LOW LIQUID PLASTIC CASING <br /> 4P). If the Hydrostatic Tank #7686-1870 SWITCH <br /> Monitor is used in areas of DAYCO/NATIONAL <br /> the country where ambient DAYTON, OHIO <br /> temperatures or delivered <br /> product temperatures may Fiberglas Reservoir Sensor <br /> subject the tank to freezing All Model DWT-2P and DWT- The reservoir sensor is also i <br /> conditions, an antifreeze 4P tanks include a Fiberglas equipped with a high-level <br /> solution must be used to reservoir mounted on the tank float switch that will generate <br /> avoid potential tank damage. top as a standard feature. an alarm condition for an outer- Oma( <br /> After filling with liquid, the wall leak in a high groundwater <br /> Brine Antifreeze Solution level in the Fiberglas reservoir condition. <br /> As an optional accessory, may be monitored periodically <br /> O/C TANKS can supply a cal- by using a dipstick or contin- To prevent the intrusion of <br /> cium chloride solution which uously by using the optional groundwater into the reservoir <br /> is pre-mixed and blended to reservoir sensor, in conjunction for extreme high groundwater <br /> provide freeze protection to with an optional electronic conditions, the factory-drilled <br /> –40°F. control panel. vent holes in the PVC riser pipe <br /> top must be plugged and a <br /> Glycol Antifreeze The monitoring sensor is separate vent line installed <br /> Solutions placed into the Fiberglas from the riser pipe to above <br /> A mixture of water and either reservoir through a 4" riser grade. In addition, the PVC <br /> ethylene glycol or propylene pipe (6" diameter for 10, riser pipe top should be glued <br /> glycol (contractor provided) diameter tanks) from grade. to the riser pipe fitting. <br /> is an alternate to provide pro- The sensor includes the riser <br /> tection against freezing. Local pipe cap with a 16" length of <br /> environmental codes should flexible conduit, which is con- <br /> be reviewed for chemical nected to an electrical junction <br /> acceptability—particularly box (contractor supplied). The <br /> if ethylene glycol is used. reservoir sensor has sufficient <br /> cable length for a maximum <br /> A minimum of 30% ethylene tank burial depth of 101 from <br /> glycol or 35% propylene the tank top to grade. <br /> glycol and water solution is <br /> recommended. At or above The reservoir sensor operates <br /> these minimum glycol con- on the principle of conductance <br /> centrations, an antifreeze to detect the presence of liquid <br /> mixture which freezes will in the Fiberglas reservoir. <br /> contract in volume, thus Under normal conditions, the <br /> preventing damage to the titanium metal probes will be <br /> monitoring components, tank immersed in the liquid media, <br />