My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1992
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2650
>
2300 - Underground Storage Tank Program
>
PR0232573
>
INSTALL_1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 11:53:13 AM
Creation date
11/8/2018 9:39:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1992
RECORD_ID
PR0232573
PE
2361
FACILITY_ID
FA0003941
FACILITY_NAME
ORCHARD SUPPLY HARDWARE #1570
STREET_NUMBER
2650
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21307061
CURRENT_STATUS
02
SITE_LOCATION
2650 MACARTHUR DR STE A
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MACARTHUR\2650\PR0232573\INSTALL 1992.PDF
QuestysFileName
INSTALL 1992
QuestysRecordDate
8/2/2017 4:00:35 PM
QuestysRecordID
3544491
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installation Instructim <br /> Electronic Control Panel Models SB0011B and SB0014B <br /> Installation of Model S80011 B is detailed in this section and Figure B. <br /> ference Figure C for model SB001 Q circuit diagram. D3. Sensor Circuit <br /> ModeISB0011B The pre-assembled reservoir sensor is ready to wire(contractor supplied). <br /> to the control panel.For intrinsically safe wiring,use 16 AWG or 14 AWG. <br /> type THHN or type MTW(contractor supplied).For U L rated applications <br /> the maximum wiring distance between the sensor and control panel is <br /> 1,750 feet.The wiring for the sensor circuit enters the right conduit at the <br /> bottom of the control panel and is connected to terminals S1 &G1. <br /> eAlIrBurton Alarm Test <br /> Bunon Model SB0011B <br /> Normal Light Shown Qolarm Light <br /> ll Silence <br /> BelS o a a <br /> Padlock <br /> Hasp <br /> ModeISB00146 <br /> Power CircuitGrountl Sensor Circuit <br /> (To 120 Volts AC) Lug (To Sensor Assembly) <br /> round <br /> Bell Silence To G <br /> Button <br /> rAlarmLight <br /> On the four circuit control panel(Model SB0014B),there are four terminal <br /> Alarm Test pairs(S1,G1 S2,G2 S3,G3 S4,G4).Connect a separate sensor to <br /> Burton each terminal pair.If less than four monitoring circuits are used,a <br /> jumper wire is required to separately connect each unused <br /> terminal pair. <br /> ormal Light <br /> D4. Optional Warning Device Circuit <br /> Alarm The tank owner may specify additional warning devices to be provided by <br /> Bell the contractor.The optional warning device circuits enter the panel at the <br /> Padlock center conduit. , <br /> Hasp <br /> Transmission Contact Switch <br /> An automatic telephone dialer typically requires only a contact switch to <br /> D1. Location activate the dialing function.The telephone dialer is plugged(or wired <br /> WARNING:LOCATE THE CONTROL PANEL IN A NOW directly)into an electrical outlet for the power source.The power source <br /> HAZARDOUS AREA WH ERE AN EXPLOSIVE ENVIRONMENT WI LL for the dialer is not supplied by the control panel.With power to the con- <br /> NEVER EXIST.The control panel can be wall mounted using the trol panel,normally closed contacts are at terminals and 4.These ter- <br /> provided mounting hardware. minals will open—providing the switching mechanism to activate the <br /> dialer—when the control panel goes into the alarm mode. <br /> D2. Power Circuit ModeISB00118 <br /> The control panel is pre-assembled and ready to wire.A120 volt AC Shown <br /> power source Is required.All wiring must be in accordance with local _ ' <br /> codes.The power circuit wiring(contractor provided)enters the lett con- <br /> duit at the bottom of the control panel and is connected to terminals Ll ;2 <br /> and L2. <br /> ModeISB0011B <br /> Shown <br /> Power Cl ACi Sensor Cimua <br /> (TO 120 Valb AC) swdChI Ro Sevarwuemdy) <br /> To GrourM swNcOClr<ud <br /> Power Circuit Phone Dia Telephone <br /> no f20volts AC) Phone <br /> Dialer Lkre <br /> o a s Q <br /> Ll H <br /> Power Source Switch <br /> • Power Circuit Ground Atypic al wiringdiagram is provided for accessories requiring power such <br /> (To 120 Volts AC) Lug asap ht beacon.The wiring diagram see Figure will provide 120 volts <br /> To Ground 9 9 9 ( 9 ) <br /> AC;the optional warning device must berated for 300 watts or less. <br /> A circuit breaker(contractor provided)common to other devices is - CAUTION:TO MAINTAIN LEAK DETECTION CAPABILITY,WIRING <br /> recommended.Using a circuit breaker common to other devices will MUST BE PLACED IN WATER TIG HT CON DU IT AND JUNCTION <br /> increase the probability the tank owner is aware of a tripped circuit BOXES. <br /> breaker.if there is no power to the control panel,the alarm bell and other WARNING:TO MAINTAIN INTRINSICALLY SAFE RATING,SENSOR <br /> warning devices cannot be activated.In areas where extreme line tran- <br /> sients WIRING(INTRINSICALLY SAFE)MUST NOT BE PLACED IN THE <br /> Icoingoccu r,supply <br /> plys urc surge protection should be installed on the SAME CONDUIT AS NON-INTRINSICALLY SAFE WIRING. <br /> incoming supply source. , <br />
The URL can be used to link to this page
Your browser does not support the video tag.