My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
2650
>
2300 - Underground Storage Tank Program
>
PR0232573
>
REMOVAL_2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 11:55:27 AM
Creation date
11/8/2018 9:39:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2004
RECORD_ID
PR0232573
PE
2361
FACILITY_ID
FA0003941
FACILITY_NAME
ORCHARD SUPPLY HARDWARE #1570
STREET_NUMBER
2650
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21307061
CURRENT_STATUS
02
SITE_LOCATION
2650 MACARTHUR DR STE A
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MACARTHUR\2650\PR0232573\REMOVAL 2004.PDF
QuestysFileName
REMOVAL 2004
QuestysRecordDate
8/2/2017 4:07:09 PM
QuestysRecordID
3544641
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN�TY PUBLIC HEALTH SERVICES/ENVIRONMENTAL No DIVISION <br /> I' GST WORKSHEET FOR SITE CLOSURE EVALUATION <br /> DATE \ <br /> NAME OF FACILITYLllrAia�O SWEEPS CODE <br /> ADDRESS <br /> TANK ID <br /> TANK SIZE �j'� FUEL TYPE W'p <br /> 11. GENERAL SITE HISTORY <br /> Is permit current? Yes No Permit 0 - *** <br /> Facility Status Code Doc.Soi l/GW Cont Yes No <br /> Number of Tanks at facility Age of Tanks(if available <br /> \Gr- \ Type of Tank Steel dlrbrgL Sngt Dual <br /> 111. TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test ? Yes No If yes, give date(s) <br /> Was a repair made to the tank system? Yes No If yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed? Yes No BTXE TPH-G TPH-D Pb/EDB <br /> Type of fai Lure/discharge catastrophic long-term leakage overfill unknown other: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes No Depth to Ground Water ` Ref Year\ \cAverage Annual Precipitation A= 14 10-25 <br /> On-Site WeLL(s) Yes No Number & Type Irr Dan Pub <br /> Distance to Wells) from Tank ftp S Score S Score S Score <br /> ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potential Analysis E is met E is met <br /> E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) >100 51-100 <br /> 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) None q Unknown <br /> Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10-25 xxxxxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration <br /> of leachate (i.e., septic systems, water wells, ponds) None O� Unknown <br /> Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. At least <br /> q More than <br /> xxxxxx None one one <br /> COLUMN TOTALS»>TOTAL POINTS + 3\p + - <br /> Sample Result: (B T X OR E) RANGE OF TOTAL POINTS 49 pts or more 41 - 48 pts 40 pts or Less <br /> !�D 8 T X E 8 T X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. E NA\3 <br /> Sample RR.essuyl,tt:� �� _ _ GASOLINE 1000 100 10 <br /> 9W�^�R<a• MAXIMUM ALLOWABLE TPH LEVELS (PPM) <br /> \O Vo kp TPH IESEL 10,000 1 1000 100 <br /> FOOTNOTES: ***If documented soil and/or ground water contamination is present, do not complete the teaching potential <br /> analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> STAFF RECOMMENDATION/CONCLUSION <br /> 1. Are BTX & E or TPN Concentrations > Allowable Levels *Yes No / <br /> 2. Recommend Site Closure Yes No If Yes, Refer to Site Mitigation for Evaluation <br /> I. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CONCUR,,WITH STAFF RECOMMENDATION FOR CLOSURE YES 0 REFERRED TO SITE MITIGATION FOR EVALUATION YES NO <br /> DATE REFERRED / / DATE CLOSURE LETTE <br /> NAME OF <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 -- <br />
The URL can be used to link to this page
Your browser does not support the video tag.