' Underground Storage Tank Remo and Assessment <br /> Sears Unit, #0555, Tracy, California <br /> ' 3.4 Soil Assessment <br /> Soil assessment samples were collected immediately under the removed UST at both ends and in the <br /> ' center of the removed UST. The three soil samples were collected at an approximate depth of 9.5 feet <br /> bgs. In addition, one sample was collected from beneath the pipe joint at a approximate depth of 9.5 feet <br /> bgs and two samples were collected from the excavated soil (one separate sample each from the tank <br /> excavation and piping excavation stockpiled soils). No visual impacts or odors were detected in the soils. <br /> ' The six soil samples were packed in a pre-chilled cooler and delivered to Sequoia Analytical for analysis <br /> as detailed in Section 3.1. <br /> ' SVOCs and VOCs were not detected in any analyzed soils samples. With the exception of concentrations <br /> of diesel and motor oil range organics and TRPH detected in the piping stockpile sample#0452SS003 <br /> (10,28,and 68 milligrams per kilogram [mg/kg],respectively),TPH and TRPH were not detected in <br /> analyzed samples. These detected concentrations are below the Regional Water Quality Control Board <br /> ' Screening Level for Threat to Groundwater for TPH and TRPH of 100 mg/kg. Metals were detected in <br /> all six soil samples at concentrations below each corresponding California Total Threshold Limit <br /> ' Concentration(TTLC)reference value. Analytical results for the assessment samples are presented in <br /> Tables 1 and 2 and sample locations are included on Figure 3. The complete laboratory report is included <br /> in Appendix B. <br /> ' 3.5 Aboveground Storage Tank (AST) Installation <br /> Prior to removal of the UST system,Three Kings installed a replacement AST within the warehouse <br /> ' building on December 20,2004. A 500-gallon Convault Secondary Containment Fireguard AST was <br /> installed in the northwest comer of the building. The AST includes an emergency vent on the secondary <br /> ' containment, a leak alarm counsel, and a double diaphragm pump to transfer waste oil to the AST. <br /> MACTEC provided the AST specifications to the City of Tracy Fired Department prior to installation for <br /> ' confirmation that the AST met applicable specifications. MACTEC received confirmation that the AST <br /> met the City of Tracy Fire Department standards and specifications on November 24, 2004. <br /> 1 <br /> 5 MACTEC Engineering and Consulting, Inc. <br />