INSTALL 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C. REQUIRED SUBMITTALS <br /> The following information shall be submitted to San Joaquin County Environmental Health <br /> Department prior to an installation plan review: <br /> 1. TO BE SUBMITTED WITH APPLICATION: <br /> ❑ San Joaquin County EHD Service Request Form and Fee Sheet <br /> ❑ Completed Underground Storage Tank System Installation Permit application <br /> ❑ Completed: UPCF Underground Storage Tanks - Facility form (A); UPCF <br /> Underground Storage Tanks (B)-Tank (one form per tank) <br /> ❑ Manufacturers' cut sheets for tanks, piping, and equipment (e.g. monitoring <br /> equipment, overspill containment device, overfill protection device, dispenser <br /> pan, etc.) <br /> ❑ Buoyancy calculations signed by a Professional Engineer <br /> ❑ 3-sets of plans of the facility and underground storage tank system along with <br /> specifications on all materials to be used in construction <br /> ❑ Payment of appropriate permit fees <br /> DRAWINGS SHALL INCLUDE THE FOLLOWING: <br /> ❑ Plans must be drawn to scale in non-erasable ink <br /> ❑ Tank cross-sectional drawing <br /> ❑ Detail of tank, associated piping, excavation and cover <br /> ❑ Plot plan to show location of tanks and all associated piping <br /> ❑ Striker plates or drop tube-mounted bottom protectors illustrated below all <br /> accessible openings <br /> ❑ Under-dispenser containment connections <br /> ❑ Detail of secondary containment installed for all unused tank opening that are <br /> connected to the primary space of the UST <br /> ❑ Detail of sumps and under-dispenser containment to demonstrate vapor tightness <br /> ❑ Detail of system that demonstrates it is impervious to water intrusion. <br /> ❑ Overfill prevention system <br /> ❑ Location of all monitoring equipment <br /> ❑ Location of water wells, septic systems, and storm drains. <br /> Note: Enhanced Leak Detection (ELD) must be performed prior to the final inspection. <br /> Revised 7/26/2016 4 <br />