My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I. MONITORING: All monitoring equipment must be listed in the State Waster Resources Control Board <br /> Division of Clean Water Program Local Guidance Letter 113. <br /> Check Code <br /> Box Section <br /> All secondary containment units (e.g. tank annular spaces, secondary piping, sumps, <br /> X� <br /> 23 <br /> CR under-dispenser containment, etc.) monitored for leaks using approved electronic leak <br /> 2636(1) detections stems. <br /> All sensors must be located at the lowest possible point so that they may detect a leak <br /> at the earliest opportunity. <br /> Electronic monitoring sensors located at the following points: <br /> ° At the bottom of the interstitial space of each secondarily-contained tank, <br /> positioned as near as possible to the bottom of the tank. <br /> Manufacturer VEEDER-ROOT Model V/R794380-303 <br /> ° In each collection sump, positioned as near as possible to the bottom of the <br /> collection sump. Additionally, in any sump acting as secondary containment for <br /> unused tank openings which connect to the primary space. <br /> ❑x 23 CCR Manufacturer VEEDER-ROOT Model V/R330020-536 <br /> 2630(d) <br /> ° In dispenser pans which do not drain into secondary containment piping. <br /> (Note:A mechanical switch which triggers a shear valve may be substituted but <br /> this system will not qualify for the annual line tightness test exemption under 23 <br /> CCR 2636(g)). <br /> Manufacturer VEEDER-ROOT Model VIR330020-536 <br /> Along secondarily-contained pipe runs which do not meet the 1/4 inch-per-foot <br /> slope requirement, positioned in the depressed or low-lying areas. <br /> Manufacturer Model <br /> 23 CCR Automatic line leak detectors installed to monitor underground pressurized piping. <br /> 2636(1) <br /> X❑ HSC Manufacturer VEEDER-ROOT Model 848480-001 <br /> 25290.1 h <br /> 25290.2 <br /> Alarm panel provides both audible and visual alarms. It is located in a protected area <br /> and within sight and hearing distance of on-site personnel and hard-wired to a <br /> x2332 cj(2)(B) dedicated circuit. <br /> Manufacturer VEEDER-ROOT Model TLS-350 PLUS <br /> J. OTHER COMPONENT INFORMATION: <br /> COMPONENT MANUFACTURER MODEL COMPOSITION <br /> CONTAINMENT SOLUTIONS OWPTSLK(W734)42/8-5 FIBERGLASS <br /> SUMP <br /> UNDER-DISPENSER BRAVO BRAB8000-F3L-BD-AB FIBERGLASS <br /> CONTAINMENT <br /> PENETRATIONS SMITH FIBERGLASS SM1012030-626-0 FIBERGLASS <br /> Revised 7/26/2016 8 <br />