My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1490
>
2300 - Underground Storage Tank Program
>
PR0541436
>
INSTALL 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 1:59:23 PM
Creation date
11/8/2018 9:40:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0541436
PE
2351
FACILITY_ID
FA0023750
FACILITY_NAME
AGS FUEL INC DBA CIRCLE K CHEVRON
STREET_NUMBER
1490
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1490 S MAIN ST
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\1490\PR0541436\2018 INSTALL.PDF
QuestysFileName
2018 INSTALL
QuestysRecordDate
5/2/2018 6:57:48 PM
QuestysRecordID
3878462
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
501
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DWT-6 DWB-2 (10')- 12M/8M <br /> 11873 Gals <br /> DIPSTICK GALLONS DIPSTICK GALLONS <br /> 108 1/8 11379 114 1/8 11716 <br /> 1081/4 11387 1141/4 11721 RECEIVE® <br /> 108 3/8 11395 114 3/8 11726rCOOLNTAINMENT108 1/2 11404 114 1/2 11732UTIONS <br /> 108 5/8 11412 114 5/8 11737 r1 NOV 3 0 201 <br /> 108 3/4 11420 114 3/4 11742 <br /> 108 7/8 11428 114 7/8 11747 ENVIRONMENTAL HEALTH <br /> 109 11436R115 <br /> V3/411781 <br /> HOW TO PROPERLY GAUGE YOUR TANK: DEPARTMENT <br /> 109 1/8 11444 <br /> 109 1l4 11452 Underground storage tanks require periodic measurement to determine current inventory level. Using the <br /> 109 3/8 11460 proper methods when gauging your tank's contents will insure the most accurate reading and insure that you <br /> 109 1/2 11468 do not damage your tank. The following procedure should be followed whenever you use a gauge stick to <br /> 109 5/8 11475 determine the amount of product that is your tank: <br /> 109 3/4 11483 1) Use a wood dipstick with a rubber or nylon Op. Metallic dipsticks are not recommended. This will insure <br /> 109 7/8 11491 115 7/8 1 11786 that frequent tank gaugings or an accidental dropping of the gauge stick into the tank will not damage the <br /> 110 11498 116 11790 tank bottom. <br /> 110 1/8 11506 116 1/8 11794 2) Slowly lower your gauge stick into the fill port until it touches the tank bottom. Never free drop the gauge <br /> 110 1/4 11513 116 1/4 11799 stick. This can result in inaccurate measurements due to product splashing. Free dropping can also result <br /> 110 3/8 11521 116 3/8 11803 in gauge stick damage and tank damage. <br /> 110 1/2 11528 116 1/2 11807 3) Remove your dipstick slowly and read the product level directly from the gauge stick. <br /> 110 5/8 11535 116 5/8 11811 <br /> 110 3/4 11543 116 3/4 11815 Water Paste Detection <br /> 110 7/8 11550 116 7/8 11818 To detect water in the tank bottom,water detection paste is available from petroleum equipment distributors. <br /> 111 11557F71 <br /> 11822 However,some water detection paste c5nnot detect antifreeze mixtures. If antifreeze mixtures are used for <br /> 111 1/8 11564 11826 the cavity monitoring fluid,the following product is capable of detecting water or antifreeze(brine or up to 50 <br /> 111 1/4 11571 11829 percent glycol)solution in the tank water bottoms: <br /> 111 3/8 11578 11833 WATER FINDER#7686-1870 <br /> 111 1/2 11585 11836 DAYCO/NATIONAL <br /> 111 5/8 11592 11839 DAYTON,OH <br /> 111 3/4 11599 117 3/4 11842 TEL: 1-800-283-2926 <br /> 111 7/8 11605 117 7/8 11845 FAX: 1-800-688-4854 <br /> 112 11612F81 <br /> 11848 <br /> 112 1/8 11619 11851 Caution <br /> 112 1/4 11625 11854 Pressurized deliveries are not recommended. If the delivery vehicle uses pumps to fill the tank, install <br /> 112 3/8 11632 11856 overfill shutoff equipment in the tank and truck to prevent the tank from being overfilled. Overfilling the <br /> 112 1/2 11638 11859 tank under pressure will damage the tank even if the tank vent is unrestricted. <br /> 112 5/8 11644 11861 <br /> 112 3/4 11651 11863 <br /> 112 7/8 11657 118 7/8 11865 Containment Solutions,Inc. <br /> 113 11663 119 11867 5150 Jefferson Chemical Road <br /> _113 1/8 11669 119 1/8 11868 Conroe,7X 77301 <br /> 113 1/4 11675 119 1/4 11870 Tel:409-756-7731 <br /> 113 3/8 11681 119 3/8 11871 Fax:409.756.7766 <br /> 113 1/2 11687 119 1/2 11872 <br /> 113 5/8 11693 119 5/8 11873 <br /> 113 3/411699 <br /> 113718 11704 <br /> 114 11710 <br /> Comp-A Containment Solutions, Inc. Confidential Page 4 <br />