)ECEIVED <br /> SWRCB,January 2002 A�!" 14 2013 Page of <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TM,,W ".'IITAI <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard _:`','._X Professional_E gineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br /> UDC# 1&2 UDC#3&4 UDC#5&6 UDC#7&8 <br /> UDC Manufacturer: Bravo Bravo Bravo Bravo <br /> UDC Material: Coated Steel Coated Steel Coated Steel Coated Steel <br /> UDC Depth: 8" 8" 8" 8" <br /> Height from UDC Bottom to Top Enters from bottom Enters from bottom Enters from bottom Enters from bottom <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to Enters from Bottom Enters from Bottom Enters from Bottom Enters from Bottom <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Dry Dry Dry Dry <br /> testing: <br /> Portion of UDC Tested Water Level 6" Water Level 6" Water Level 6" Water Level 6" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both Yes X No ❑NA Yes X No ❑NA Yes X No ❑NA Yes X No ❑NA <br /> product and water)?. <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fail- X Yes ❑No ❑NA X Yes Ci No ❑NA X Yes ❑No ❑NA X Yes ❑No Ci NA <br /> safe shutdown?* <br /> Was fail-safe verified to be Yes X No ❑NA ❑Yes X No ❑NA ❑Yes X No ❑NA ❑Yes X No [INA <br /> operational?* <br /> Wait time between applying 5 Minutes 5 Minutes 5 Minutes 5 Minutes <br /> water and starting test <br /> Test Start Time: 8:40 8:45 8:50 8:55 <br /> Initial Reading(111): .001 .001 .001 .001 <br /> Test End Time: 9:10 9:15 9:20 9:25 <br /> Final Reading(RF): .001 .001 .001 .001 <br /> Test Duration: 30 Minutes 30 Minutes 30 Minutes 30 Minutes <br /> Change in Reading(RF-Rj): 0 0 0 0 <br /> Pass/Fail Threshold or Criteria: .005/30 Minutes .005/30 Minutes .005/30 Minutes .005/30 Minutes <br /> Test Result: Pass Pass Pass Pass <br /> Was sensor removed for testing? X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No ❑NA <br /> Was sensor properly replaced and X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No ❑NA X Yes ❑No ❑NA <br /> verified functional after testin . <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />