My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
3440
>
2300 - Underground Storage Tank Program
>
PR0231173
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:18 PM
Creation date
11/8/2018 9:41:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231173
PE
2361
FACILITY_ID
FA0006423
FACILITY_NAME
CENTRAL GAS STOCKTON
STREET_NUMBER
3440
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3440 E MAIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\3440\PR0231173\COMPLIANCE INFO 2013 - 2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Op'•4u'IN••C � 1�� <br /> SAN JOAOUIN COUNTY 1LL! <br /> (2 —cry ENVIRONMENTAL HEALTH DEPARTMENT <br /> �y 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> c•• P Telephone:(209) 468-3420 Fax:(209) 468-3433 Web:www.slgov.org/ehd <br /> 4��FORN` <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> Facility Name: Inspection Date: <br /> Facility Address: Service Request#- <br /> 0 AA <br /> q q 341 <br /> Onsite Service Technician's Name: ICC Service Technician/Installer Exp. Date: Manufacturer Training: <br /> S )0 ,5 V 1 zZc, ul z <br /> SERVICE SERVICE <br /> x Leak detector Spill bucket El minimum 5 gallon <br /> X5Zmechanical Model: fT4 Z '� I El El hour hydrostatic El Incon TS-STS <br /> El electronic Serial #: ❑ Caldwell System ❑ Other <br /> ❑ line test programmed <br /> Leak detector <br /> El mechanical Model: Spill bucket El minimum 5 gallon <br /> ❑ El E-1❑ electronic Serial #: 1 hour hydrostatic ElIncon TS-STS <br /> ❑ line test programmed <br /> El Caldwell System ❑ Other <br /> sensor <br /> ❑ positive shutdown Model: psi <br /> Primary piping testing at: <br /> ❑ D fail safe Serial #: ❑ minutes <br /> ❑ NA <br /> sensor Secondary containment testing for: <br /> ❑ ❑ positive shutdown Model: UDC(s) Piping <br /> ❑ fail safe Serial #: Sump(s) UST(s) <br /> ❑ NA <br /> sensor ❑ Testing for the above components are next due by: <br /> ❑ ❑ positive shutdown Model: <br /> ❑ fail safe Serial #: Note: Please be aware that 2'containment components are required to be tested upon <br /> ❑ NA installation.6 months after.and every 36 months thereafter <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Cold start of monitoring panel <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Corrosion protection <br /> ❑ Overfill prevention (see LG letter 150-1) ❑ Other: see below <br /> ( This UST facility is APPROVED to operate ❑ This UST facility is NOT APPROVED to operate <br /> k ' <br /> teS <br /> uAA SV <br /> Q <br /> 11 <br /> THISYAgfLITY IS PYBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> EHD Ip WC!or ,-/, Received By: Title: <br /> L L <br /> EH[ 23- UST SERVICE REQUEST INSPECTION REPORT <br /> Rev 4/30 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.