My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 12:06:34 PM
Creation date
11/8/2018 9:41:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 2000-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> � ip TanknakW rUse By All Jurisdictions Within the State of Calif, <br /> Authority Cited.Chapter 6. e/th and Safety Code;Chapter 16, Division 3 Title a/ifomia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each mons onng system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> sys em owner operator. a owner opera r mus su ml a copy o is ortn o e local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: ULTRAMAR492 City: MANTECA CA Zip:95336 <br /> Site Address: 470 N MAIN ST Contact Phone No:823-1344 <br /> Date of Testing/Service: 12/12/2002 <br /> Facility Contact Person: MANAGER <br /> Make/Model of Monitoring System: GBCO EMC Work Order Number: 2224699 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: UNLEADED Tank ID: SUPREME <br /> In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: MAG <br /> Annular Space or Vault Sensor. Model: GBCO 010 X Annular Space or Vault Sensor. Model: GBCO 010 <br /> Piping Sump/Trench Sensor(s). Model: GBCO 000 X Piping Sumprriench Sensor(s). Model: GBCO 000 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Madel: <br /> Mechanical Line Leak Detector. Model: RJ FX1 V X Mechanical Line Leak Detector. Model.. RJ FX1V <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overrill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> an an <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sumpfrrench Sensor(s). Model: Piping Sumpri-rench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overall/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser lu. Spenser <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensors) Model: <br /> ®Shear Valve(s). Shear Valve(s) <br /> ®Dispenser Containment Float(s)and Chaints). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Ispenser <br /> ❑ Dispenser Containment Sensors) Model: Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: <br /> F] Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). Shear Valve(s). <br /> ® Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up report; ❑ Alarm history report <br /> PRINTED NAME:KEVIN MATLOCK SIGNATURE: <br /> COMPANY: Tanknology PHONE NO: (800)800-4633 <br /> page 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.