My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 12:06:34 PM
Creation date
11/8/2018 9:41:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 2000-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUARETANK INFORMATION AND TEST RESULTS <br /> Tanlowillogy <br /> 8900 SHOAL CREEK, BUILDING 200 WORK ORDER NUMBER: 2220022 <br /> TEST DATE: 12/19/01 AUSTIN,TEXAS 78757(512)451-6334 <br /> CLIENT: ULTRAMAR INC SITE: ULTRAMAR 492 <br /> Tank ID: 87 1 Tank manifolded: NO Bottom to top fill in inches: 134.0 <br /> Product: UNLEADED Vent manifolded: YES Bottom to grade in inches: 141.0 <br /> Capacity in gallons: 14,130 Vapor recovery manifolded: yES Fill pipe length in inches: 38.0 <br /> Diameter in inches: 96.00 Overfill protection: yEs Fill pipe diameter in inches: 4.0 <br /> Length in inches: 337 Overspill protection: yEs Stage I vapor recovery: DUAL <br /> Material: Dw STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> 4t <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: RED JACKET <br /> Fluid volume in gallons: Model: FXIV <br /> Tank water level in inches: SIN: 4079811410 <br /> Test time: NOT Open time in sec: 3.00 <br /> Number of thermisters: TESTED Holding psi: 19 NOT <br /> Specific gravity: Resiliency cc: 125 TESTED <br /> Water table depth in inches est leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 10 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> Test time: Material: DW FIEERG <br /> Ullage volume: Diameter(in): 2.0 <br /> Length(ft): 40.0 <br /> Ullage pressure: <br /> Results: Test psi: 50 <br /> Bleedback cc: 120 <br /> DATA FOR UTS4T ONLY: Test time (min): 30 <br /> Test 1:Start time: 11:00 <br /> Time of test 1: Finish psi: 50 NOT NOT NOT <br /> Temperature: NOT Vol change cc: 0 TESTED TESTED TESTED <br /> P Test 2:Start time: 11:10 <br /> Flow rate (cfh): TESTED Finish psi: 50 <br /> Time of test 2: Vol change cc: 0 <br /> Test 3:Start time: 11:20 <br /> Temperature: Finish psi: 50 <br /> Flow rate(cfh): Vol change cc: 0 <br /> Time of test 3: Final gph: 0.000 <br /> Temperature: Result: PASS <br /> Flow rate (cfh): Pump type: PRESSURE <br /> COMMENTS Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: yEs <br /> Printed 12/28/2001 13:14 LFRISK <br />