My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 12:06:34 PM
Creation date
11/8/2018 9:41:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 2000-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•nitoring System Certification • <br /> Site Address: 470 N MAIN ST Date of Testing/service: 12/19/2001 <br /> D. Results of Testing/Servicing <br /> Software version Installed: <br /> complete the following checklist: <br /> MEErn <br /> s the audible alarm operational?Is thevisual alarm operational?ere all sensors visually inspected,functionally tested,and confirmd operetioere all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br /> interfere with their proper operetionIf alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> © Yes ❑No* ❑N/A monitoring system detects a leak,fails to oppe�rate,or is electrically disconnected?If yes:which sensors inflate positive <br /> shut-down?(check all that apply) LXf Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and5ensor failure/disconnection? ❑x Yes Lj No <br /> * ❑ For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.:no mechanical <br /> © Yes ❑No N/A <br /> overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill poinis(s)and operating <br /> property? If so,at what percent of tank capacity does the alarm trigger? 90 OA <br /> ❑ Yes* ©No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement arts in Section E,below. <br /> Was liquid found inside any secondary containment systems designed as dry systems?(check all that apply) <br /> El Yes* ©No ❑Product; <br /> ❑ Water. If yes,describe causes in Section E,below. <br /> © Yes ❑No* Was monitoring system set-up reviewed to ensure proper settings?Attach set-up reports,if applicable. <br /> © Yes ❑No* Is all monitoring equipment operational per manufacturers'specifications? <br /> *In Section E below,describe how and when these deficiences were or will be corrected. <br /> E. Comments: <br /> page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.