My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
470
>
2300 - Underground Storage Tank Program
>
PR0231441
>
COMPLIANCE INFO 2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2022 12:06:34 PM
Creation date
11/8/2018 9:41:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231441
PE
2361
FACILITY_ID
FA0003604
FACILITY_NAME
BEACON STATION #3492*
STREET_NUMBER
470
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22307101
CURRENT_STATUS
02
SITE_LOCATION
470 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\M\MAIN\470\PR0231441\COMPLIANCE INFO 2000-2005.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
204
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br /> SWRCB,January 2002 Page -�—of� . <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer O-Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum gHydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: rJ CO r\. Equipment Resolution: 7 0, o oz <br /> F1il Sum # Fill Sump#S Fill Sum # Fill Sump# <br /> Sump Diameter: Lly s <br /> Sump Depth: <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest I � �, <br /> Electrical Penetration: <br /> Condition of sump prior to <br /> testing: ($K © K <br /> Portion of Sump Tested I( n t <br /> Sump Material: i as <br /> Wait time between applying <br /> pressure/vacuum/water and $M�h <br /> starting test: <br /> Test Start Time: 12,3D 23 O <br /> Initial Reading(RJ: 5. D }� <br /> Test End Time: W L45 <br /> Final Reading ): . I 3 1 <br /> Test Duration: I5 M i h I S rr,I), <br /> Change in Reading Ril: } 6,Ooo(, _ 0 4DO <br /> Pass/Fail Threshold or Criteria: {_ p , 002- f p. O D z <br /> Test Result: 6-Pass ❑Fail &Pass ❑Fail D Pass ❑Fail <br /> Is there a sensor in the sump? @KYes ❑No 19Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is 19LYes ❑No ❑NA RYes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed Tor testing? ! yes ❑No ❑NA RYes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and Yes ❑No ❑NA <br /> verified functional after testis ? l Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Continents—(include in onnation on repairs made prior to testing and recommended allow-up for ailed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.