Laserfiche WebLink
MONIT NG SYSTEM CERTIRUTION <br /> e By All Jurisdictions Within the State of Califomi <br /> Authority Cited:Chapter 6.7,H and Safety Code;Chapter 16,Division 3 Title 23, omia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system opntrol panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this forth to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: ULTRAMAR 492 City: MANTECA CA Zip:95336 <br /> Site Address: 470 N MAIN ST Contact Phone No: 823-1344 <br /> Date of Testing/Service: 11/22/2005 <br /> Facility Contact Person: MANAGER <br /> Make/Model of Monitoring System:TLS350 Work Order Number: 2239393 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment Inspected/serviced <br /> TanklD: 1 TanklD: 2 <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 420 Annular Space or Vault Sensor. Model: 420 <br /> 71 Piping Sump/Trench Sensor(s). Model: 208 Piping Sumprrrench Sensor(s). Model: 206 <br /> X Fill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Model: 208 <br /> Mechanical Line Leak Detector. Model: FX1 V Mechanical Line Leak Detector. Model: FX1V <br /> 71 <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank OverfilUHigh-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> TanRID. TanklD: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank OverfilVHigh-Level Sensor. Model: Tank Overfill/High-Leval Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser[L): 1/2 Dispenser ID: 3/4 <br /> QDispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s) Model: <br /> X❑Shear Valve(s). X Shear Valve(s) <br /> QX Dispenser Containment Float(s)and Chain(s). X Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser UID.. <br /> 7/8 <br /> MDispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> Xi Shear Valve(s). Shear Valve(s). <br /> X Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser IU: <br /> Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> •If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this Information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ❑X System set-upX❑Alarm history report <br /> Technician Name(print): RHOME DESBIENS Signature: i <br /> Certification No.: 1938 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 11/22/2005 <br /> Page 1 of 3 Based on CA form dated 03/01 <br /> Monitoring System Certification <br />